Ferroli optimax he38c fault code f37

Joined
19 Jan 2008
Messages
36
Reaction score
2
Location
Liverpool
Country
United Kingdom
Today i fitted a pcb and an diverter vavle to a optimax he 38 c when i come to switch it on and fire it up f37 is on the display. f37 is system pressure to low but it was at 1.5 bar any suggestions anyone
 
Sponsored Links
Sponsored Links
just a switch C NO & NC you would get continuity between C NO if there is 1bar in the boiler, but if there is 1 bar in the blr an continuity between C NC then its fooked

this is a standsrd Low wtr pressure switch.
 
Check the perameters in the pcb u might find it thinks it has pressure switch rather than sensor happens all the time
 
hello michael, are you new to boiler repairs? I suggest you attend a fault finding course an teach yourself electrics & how to use a multi meter


;)
 