Securitech active 5 reset

Joined
28 Nov 2015
Messages
2
Reaction score
0
Country
United Kingdom
Hi

I had my main electric off for a few days and when i switch it on the alarm goes off. I tried the code given to me by the estate agent aswel as 1234 and 7890 but nothing works. I have taken the fuse out to disable the whole system. I have read in the engineer manual the following:

Remove all power from the cotrol panel, fit default link CN6, reapply power remove default link CN6.

I cannot find a CN6. Please see the photo attached. Can anybody help?

Thanks
 

Attachments

  • 20151127_211844.jpg
    20151127_211844.jpg
    158.6 KB · Views: 1,172
Sponsored Links
It's under the keypad you have to unplug it !
Right hand side of pcb link 2
 

Attachments

  • image.jpg
    image.jpg
    110.6 KB · Views: 1,412
Thanks for the reply and the attachment. I cant see anything that says CN6. Where exactly am I looking and when I find what I am looking for what do I do?

Thanks
 
Sponsored Links
Two pins ( link2 ) power down panel short the pins together ( screwdriver blade) and power up with pins shorted , remove short on pins plug keypad back on enter 1234 to stop sounder
 

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Back
Top