Search results

  1. G

    Plastic for Central heating?

    plastic might seem cheaper to buy, but the fittings are alot more expensive than copper fittings. If you are going to use plastic i would use hep20 not speedfit :lol:
  2. G

    Salus RT500RF Programmable Room Stat Questions

    The thing i find annoying about these programmers is the fact that unlike most there is no mode to cycle between heating constantly on, off or timed. So what if i have all my times set but the weather is hot and i don't want any heating on? do i have to re programm ALL my times to turn the...
  3. G

    Is this really an economical way to install a combi?

    Well there's your first mistake, you payed british gas 5k! yes 5 thousand pounds!!! to fit a combi boiler..... didn't you think that sounded expensive :? A local independant installer would have by the sounds of it done a better job for a third of the price!
  4. G

    New Thermostaic Shower Valve

    Sounds like its not mixing properly, you can take off the "tap head" and the cover and get into the cartridge and adjust the mixer valve with a pair of pliers until you find a comfortable temperature.
  5. G

    Downstairs RAD's hot when hot water on....not 3 way valve.

    can you see where the hot water return joins back into the system? It probably joins in before the downstairs rad circuit, so the hot water return is warming the rads, changing the 3 way valve won't do sh*t.
  6. G

    Conflicting servicing sheets

    If you say the inlet pressure was 20mbar when the boiler was fitted then it shouldn't be anything to do with the pipe size, unless you have had additional gas appliances installed since the boiler which would reduce the flow of gas to the boiler? Could be a blockage in the pipe/inlet to...
  7. G

    Square flue liner anyone?

    this must be a joke :lol: :shock: :lol:
  8. G

    Boiler casing holes non-repairable?

    matty you get so much abuse on this site, it confuses me as to why you actually keep posting :lol:
  9. G

    landlords gas check legal requirements

    go nag some more nagsag
  10. G

    landlords gas check legal requirements

    see i thought it took 4 mins for proper test :wink: 1 min let by test, 1 min stabilization and 2 min test
  11. G

    Ferroli combi boiler thrwing water out of overflow

    Depends, you need to drain some water out of the system first to stop it leaking out of the blow out then do a few tests. Get the pressure back to 1.5 bar then disconnect the filling loop to see if its passing water, if it is then it needs replacing. If the filling loop is fine then, you...
  12. G

    Ferroli combi boiler thrwing water out of overflow

    filling loop passing? Grit in blowout seating? Expansion vessel needs pressurising? hole in heat exchanger?
  13. G

    Bath a little short & cat iron soil stack drip

    cut the denso tape into strips to fit around the stack, then wrap them round and smooth them out with ya fingers. (sticky stuff, but its perfect for what you need) Just buy a tube of silicone and a gun, and squirt it into the gap! then smooth over with a damp finger.
  14. G

    Boiler cuts out

    get a footpump and put it on your expansion vessel, it should be around 1.5bar, pump it up if lower
  15. G

    Boiler cuts out

    does pressure rise only when you turn the boiler on? or is it constantly rising?
  16. G

    Bath a little short & cat iron soil stack drip

    Put denso tape round the soil stack not silicone. You can always cut some tiles to fill the gap and overlap on to the bath a bit, or just silicone it.
  17. G

    Look what I found under my bath.

    All commonly found things i pressume in Glasgow! :lol: :lol:
  18. G

    Brand new towel radiator leaking.....

    sure it would look beautifull, which a few welded joints on a nice smooth chrome towel rail.............. :roll:
  19. G

    Vokera 20-70 se

    if there is no power to the fan, how can it work, even if its brand new? :wink: PCB
  20. G

    Glow worm boiler won't start up on its own

    When the boiler stopped working, what made you decide to Suck then blow on a tube to see if that would fix it? :shock: Normally don't people who don't know what there doing just Hit things to try get them working rather than start sucking and blowing on random tubes? (sounds a bit filthy)...