  1. M

    Premier Elite - Firing a panel output from one of two sources

    That worked an absolute treat and also answered my question (on another thread) about what the custom outputs could be used for. The GJD floodlight system actually has 2 channels for front and rear of the house so using a relay card, £8 for an 8 relay card on ebay...
  2. M

    Premier Elite - Firing a panel output from one of two sources

    I have my (GJD) Floodlights wired up to the relay on the panel (output 5) and have set it such that in an Alarm condition they will turn on. However, I'd like to be able to also control this output (i.e. turn floodlights on/off) from the Mobile Connect App. I've worked out how to get PC Output 1...
  3. M

    Texecom Elite Outputs

    Thanks, yes that's worked. Via Wintex, I've simply set the trigger for one of the 5 wired outputs on the panel to use 'PC Output 1' - which presumably is just an 'internal output/state'. Seems an odd/added step to be able to do it but presumably the PC Outputs can serve some other purposes and...
  4. M

    Texecom Elite Outputs

    Hi, I have a premier elite 88 and would like to make it so that from the mobile 'Texecom Connect' App, I can initiate a relay (ideally for a second or so) to open my electric garage door, such that I can use the App to disarm the alarm and also open the garage door and drive in. If I add text...
  5. M

    Scantronic 9751 Reset Required

    Thanks, and do you know what the puroose of Kick Start is on these panels - is that to set it back to factory defaults?
  6. M

    Scantronic 9751 Reset Required

    Did the NVM reset only reset the pin codes, or did you have to re-program the zones etc. as well?
  7. M

    Gas Pipe beneath Beam and Block

    Thanks for your info bob, going round the outside is feasible, just is a lot more work... but thanks for expanding on why.
  8. M

    Gas Pipe beneath Beam and Block

    thanks for the reply, are you suggesting it is possible then (subject to sizing and the gas safe engineer being happy) - I just wanted to know really if it's within building regs or if the pipe needs to be buried under earth as I'm struggling to find guidance on it ? If it's likely to be...
  9. M

    Gas Pipe beneath Beam and Block

    On my new build, the ground floor construction is beam and block with a void below, vented as usual to the outside via air bricks. The Gas meter will be at one side of the house, and at the other side, 20 meters away will be the gas boiler. Whilst I have access to under the house, is it possible...
  10. M

    Soil Pipe Distance

    I'm building a house and wish to have a toilet at the rear 1st floor level. Due to the ground height at the rear of the house being lower than the sewer at the front, I cannot simply drop a stack down at the rear of the house and so wish the pipe to go to the gable end wall, which is 14m from...
  11. M

    Flow direction for Central Heating Pump

    OK, had a couple of the plumbers back in today - they didn't seem to know what had been discussed etc, but one of them came clearly knew reversing the pump wasn't an option. One had been instructed to move the pump to the utility room below, the other instead instructed not to. Anyway, they...
  12. M

    Flow direction for Central Heating Pump

    Clearly not, I called Glow Worm Tech, they too said absolutely do not let them reverse the flow - I called the builders so they are now going to look into a better solution (hopefully) - perhaps it was just a consideration but glad it wasn't followed through ! - thanks ALL !. I was thinking...
  13. M

    Alpha 2 Pump - an attempt to reduce vibrations

    Do you know if the latest Alpha 2 pumps are likely to help with vibrations? Following some un-sucessful attempts by my builders to stop a noisy airing cupboard where the pump is mounted on a stud wall, I'm wondering if switching to an Alpha 2 pump would help? (in addition to buffering the...
  14. M

    Flow direction for Central Heating Pump

    nope - not a wind up, and I think a few people have deliberated over this as a solution. I'll pass on your feelings when they arrive tomorrow ! BTW, so i can give them reasons...what are the sort of things that can go wrong when doing this?
  15. M

    Flow direction for Central Heating Pump

    Thanks for the quick reply, I've also since checked the radiator valves, whilst most are Myson TRV '2 way', the bathroom one is Drayton TRV 4. Online, some info says it (or some version of it) has 'Reverse Flow', mine has a flow arrow on the side of the valve so does this suggest it's one-way...
  16. M

    Flow direction for Central Heating Pump

    Hi, I've a new home and had trouble with a resonating noise from the pump (as it's installed on a studded wall in the airing cupboard) My problem isn't necessarily about the vibrations but more your opinions on one of the suggested solutions, having already tried several other attempts to...
  17. M

    Hot Water Cutting Out On Combi Boiler

    Hi, I've a combination boiler (Glowworm Swiftflow 100) and the following is happening. Running the hot water tap fires up the boiler as expected, but then usually after a few seconds it stops and the water runs cold. This has previously ran fine for the last 4 years. This is...