Search results

  1. D

    Underpinning

    I’m potentially going to have to do some quite drastic underpinning on my house to satisfy the structural engineer for a development we Doing,I don’t have too many options for alternatives due to having already upset planners with numerous appeals and finally winning one. looking for advice and...
  2. D

    external pir, anyone got any they could check

    Why do you say that? surely someone has some in their van :) or installs one and remembers and can snap a photo of the pcb :)
  3. D

    external pir, anyone got any they could check

    Hi, I'm looking for some 24v external pir's.. most have the possibility of being converted... if anyone has any lying around could you check the relay coil voltage for me and if it says 24vdc let me know the model of the pir so I can try and order a couple online as I cant get to a wholesalers...
  4. D

    Part M and Height Requirements

    @ban-all-sheds I like your thought but I have no chance of that one washing (pun intended) as the house is at the top of a hill.. if it floods here then I'll be building an ark! With regards to this "Height recommendations only apply to new-builds and complete refurbishments." I think timing is...
  5. D

    Electric Strike for Sash Locks

    Sorry for the delay in replying - it was a nightmare trying to use the phone to reply - ad's kept popping up over the page. @SparyMania - when they sent measurements they were nowhere near the sash lock sizes, would you mind taking a photo of one of yours with a ruler or tape next to it...
  6. D

    Electric Strike for Sash Locks

    Anyone know of any sensibly priced 24v DV electic door strikes for sash locks (IE https://www.toolstation.com/viscount-5-lever-mortice-sashlock/p95375) tried CDVI but they have nothing suitable. Thanks David
  7. D

    Part M and Height Requirements

    Hi, I believe Part M requires the breakers in an enclosure to be mounted between 1350 and 1450mm? I'm intending to change my incoming supply to a TP&N supply so I can use a decent size ASHP and solar.. Due to the DNO not wanting the new service cable running under my garage floor in a duct, a...
  8. D

    Meter box position - regs, guidelines?

    dont really think getting the jointers onboard would be happening :D and would also make the metering a bit erm.. :D
  9. D

    Meter box position - regs, guidelines?

    The price last time I looked was comparible with the move of the supply. DNO spec ducting etc isnt a problem, I've a friend who does that exact job for the DNO :D - I've also a friend who is a site manager and reguarly is skipping that kind of stuff - I'm in no rush so can wait until he has a...
  10. D

    Meter box position - regs, guidelines?

    I know it isnt, nor is the existing cable good enough, so a dig will be required to the joint at the end of my street.. outside the drive.. That wasnt my question though :)
  11. D

    Meter box position - regs, guidelines?

    I've bought a new house and looking at switching to three phase due to the size of the ASHP I may need and to help with offsetting it with solar.. I also need to move the meter anyway due to renovations so kind of makes sense. However are there any regulations (possibly new) that stipulate...
  12. D

    Lowering Floors.. Dpc.

    20180830_183617 by dw3101 posted 26 Sep 2018 at 11:07 PM20180830_183624 by dw3101 posted 26 Sep 2018 at 11:07 PMi wouldn't be digging.
  13. D

    Comment by 'dw3101' in album 'pics'

    underfloor pics
  14. 20180830_183624

    20180830_183624

  15. 20180830_183617

    20180830_183617

  16. pics

    pics

  17. D

    Lowering Floors.. Dpc.

    Hi, I'm going through with a new house purchase (bungalow) at the moment and looking doing a fair bit of work to it.. One thing I'm talking to my architect about at the moment is the possibility of lifting the eaves and the ridge height (yeah yeah I know got to get that past planning..) One...
  18. D

    Altronix in Uk or equiv product

    Does anyone know if this can be obtained in the uk, or know of an equivalent than can remotely reset outputs via ethernet? https://www.altronix.com/products/LINQ8PD
  19. D

    Any one got an old concorde 4 or equiv?

    Why do you say that? - Like rocking horse poo or I need more info?
  20. D

    Any one got an old concorde 4 or equiv?

    All I know is the panel is a concorde 4
Back
Top