    AOSMITH or Lochinvar

    Cheers guys, I am off to the ECObuild next week so will try and speak to a few chaps there to make a decision. They are both quite heavy on the gas consumption however if you want 400l heated up in 21 minutes there isn’t really any other way. Both units I am looking at are the BFC60 and...
  2. G

    AOSMITH or Lochinvar

    Does any one have any direct experience with these hot water heaters? I know that AOsmith have now pruchased Lochinvar, but it seems they are mainly used in the USA, so cant really find any forums/installers with direct experience...my concern is the reliability issues that alot of americans...
  3. G

    Flow rates - pipe size - Accumulators and Dual Stream design

    Apologies, I am not a plumber nor do I intend to give that impression sorry if I was unclear. My property is 5 floors typical Georgian London town house. Basement, ground, first, second and third floor. The apartment will be distributed: Basement - 2 bathrooms Ground - 2 Bathrooms...
  4. G

    Flow rates - pipe size - Accumulators and Dual Stream design

    I am designing a new Hot Water system for 9 apartments within a serviced block. The mains we have consists of 3 X 25 plastic inlets. I have 3.5-4 bar pressure with over 90 l/m when I put them into a manifold a test using a Hedland In line flow meter. What I intend to do is run the 3...
  5. G

    Santos Expansion Vessel

    Hi all, I have a Santos unvented system, with a Viessman Vitoden 100 heat only. The heating has its own external Exp. Vess, and the DHW has its own white slightly bigger Exp. Vess. I live in central London with very hard water, about 400 parts, and when I have a shower and someone else...
  6. G

    Another Viessmann 100 problem

    do you reckon I shoud power flush?
  7. G

    Another Viessmann 100 problem

    SOLVED Found out the installed put a strainer filter in the pipe work under the boiler which apparently he was not suppose to. We removed it and worked straight away. He diagnosed the circulation around the diverter valve and ruled out the pump. Then after looking under the countertop in...
  8. G

    Another Viessmann 100 problem

    Hi JohnD, Thanks for the reply. I have no problem with sizing as previously with the same setup the flat was always heated adequately. But all the TRVs are setup to max, and the heaters are getting hot with no airlocks. The problem Im having at the moment is with the boiler getting hot...
  9. G

    Another Viessmann 100 problem

    Guys Im a landlord and I have partially been involved with the installation. If I am CORGI or registered with Viessmann is irrelevant. The point is that Viessmann are closed this weekend, hence I wanted to see if any one could help. If there are any registered Viessmann plumbers on the...
  10. G

    Another Viessmann 100 problem

    The total sq ft of the flat is 650, and the rads are approx 60 X110 I turned the dials down didnt do anything, same problem. However I managed to get the boiler into SERV mode. DHW is on the spot and CH is now on 6. The display shows ECO and SERV. Now the boiler is going upto max...
  11. G

    Another Viessmann 100 problem

    I didn't actually think of that, I will try to lower it to maybe 3-4 on the rotary switch and see if it maintains the temp. I think if the boiler could stay at 60 deg and stay burning it will be better the current situation. Does any one have any experience with the Viessmann service people...
  12. G

    Another Viessmann 100 problem

    Indeed I installed the boiler, but didnt bother at the time with a room stat.
  13. G

    Another Viessmann 100 problem

    I just purchased the Vitoroll 100 UTD RF plugged it into X7 on the board. Setup the temp to 30 degress on the room stat still the same problem. I think the pump is fine as the Rads are getting hot however they are not staying hot. Im pretty sure its a faulty control unit of some sort...
  14. G

    GAH DualStream Problems

    Any one experience with these products? I have had installed 5 cylinders. 2 X ariston ITI 300 stainless still hot water up in the loft next to my 635 valliant system boiler 3 X 500l accumaltor in the basement which are being fed main pressure which is over 4bar and very good flow...
  15. G

    Another Viessmann 100 problem

    Hi all, I have installed 2 Viessmann boilers this year. 1st the older 100 heat only compact model. And now the new larger 100W combi version. After 12 months the compact 100 has only had the F4 problem which was fixed by a new black spark generator. The newer 100W is having a different...