Search results

  1. R

    kangoo van rear suspension dropped one side

    Thanks for reply ratm. No springs on rear, It has an axle beam with torsion bars, which i don't no to much about . Been doing some checking and i think one of these has slipped on the splines. If it is this, i'm unsure if it can be repaired or if it is an axle beam replacment. rob.
  2. R

    kangoo van rear suspension dropped one side

    Hi all, Went over some speed bumps the other day, probably to fast, and herd a clonk from the back.The suspension has also dropped on one side. ive changed the shocks as i thought this was the problem but still no good. Any ideas anyone
  3. R

    could you check this for me please

    Cheers for that. Didn,t think about sleeving fan connections. rob.
  4. R

    could you check this for me please

    Hi. Fitting in a toilet/basin under my stairs as well as a couple of gu 10 240v down lights and a timed extracter fan. All under building control. As you can appreciate everything is a bit close together. On the electric side i was going to fit a 3a fcu, from downstairs ring, within 150mm...
  5. R

    renault kangoo 1.9d cylinder head torque settings

    Hi. Does anybody know the cylinder head torque settings for a renault kangoo 655 1.9d. Engine is a f8q, year 2000. Got this van the other day and found an oil leak, among loads of other problems, from what appears to be the rear of the head. Has had a recon one fitted which is fairley...
  6. R

    switch wiring, is this ok

    Thanks plugwash. and i'll make that a 5a.
  7. R

    switch wiring, is this ok

    Hi, I want to fit an outside light, 300w pir, which i understand has to be via a fused connection unit. Also at the same time , a 60w light in my conservatory. Can i use the supply from the fcu for both and wire it as diagram?. I'm not shore if this would be a shoddy way of doing it or not.
  8. R

    msn explorer keeps hanging

    cheers breezer. at least i know the modem part is ok.
  9. R

    msn explorer keeps hanging

    Hi breezer, yep all traces removed. if modems can cause this, i may not have my tiscali one set up correctly. baring in mind it's broadband, every time i connect a small screen appears saying dial up connection connecting ,or to that effect, i dont know if this is how it should be, as with...
  10. R

    msn explorer keeps hanging

    Hi all. Running windows xp. The problem iv'e got is with my msn explorer. Log on ok, and usage ok, it's when i go to sign out, it hangs with programme not responding. Don't know if this has anything to do with it but never had a problem when i was connected to ntl broadband, it's since i've...
  11. R

    Quick question, outside socket

    Cheers andy. once again thanks for the reply's. until the next time. rob. :D
  12. R

    Quick question, outside socket

    Circuit on rcd side of cu. don't think i need another do i ?. What does tla stand for ? just curious !
  13. R

    Quick question, outside socket

    Thanks damocles. Switched fused spure plate. Is that sparky slang for an fcu ?. If so would this be ok ? ring..........internal socket.........ring. ------------------I ----------------- I -----------------fcu ----------------- I ------------------I ----------outside socket OR...
  14. R

    Quick question, outside socket

    Thanks for replies guys. Intend to mount about 400mm from the patio. Conservatory has it's own ring main.so i was going to spure off at two seperate points for two single sockets outside, ip56 rated.
  15. R

    Quick question, outside socket

    Thanks andy. Did some checking up on this and belive that the 450-1200mm rule is a building regulation for NEW DWELLINGS ONLY, and not an iee requirement, being aimed at the dissabled for ease of access. If this is correct and my conservatory is only attached to the house it does not come under...
  16. R

    Quick question, outside socket

    Hi, Tried to use search engine but can't find what i'm looking for. What i want to do is fit an mk masterseal socket on the outside wall of my conservatory by spuring of the ring main in there, which is rcd protected. Question being is there any minimum height requirement from outside...
  17. R

    House supply over head, and no main earth

    Thanks guys. Much appreciated.
  18. R

    House supply over head, and no main earth

    Area is orpington in kent, seaboard energy. ( e.d.f. ) Up grade bonding, earth block, 16mm2 to cu, meter, stopcock centralheating system. When this is done do i just call them to come and connect ?. Foward thinking hear whilst power is of do they remove the rcd ?. If so i'll have an isolator...
  19. R

    House supply over head, and no main earth

    Hi, Don't know what the best way is to go with this. Have been hours on the phone to the electricity co, being put round different departments, eventually got the technical help desk. They left a message saying they can convert to a pme connection but did not say if i have to pay or if it's...
  20. R

    House supply over head, and no main earth

    Hi all, My house is supplied by overhead cable to the service head, through the meter then a main rcd to an old type cu, which i intend to change for a split load type. The only earth i can find is connected to the gas pipe, 10.0mm, which runs to an earth block and from there to the cu. i'm...