  1. ianmcd

    Diverter valve cartridge vokera unica 28he

    Yes it will have dried out now, that was your problem even a minute spot of water will cause that on the pcb
  2. ianmcd

    Implications of heavy boiler corrosion for pipework?

    me thinks you need a proper engineer , not a new boiler
  3. ianmcd

    Diverter valve cartridge vokera unica 28he

    Did you cover the PCB housing with a towel or such before removing, the cartridge ?
  4. ianmcd

    Loud noise from 3 port valve

    I have had exactly that fault and it was a tooth on the synchron motor that was sheared off, either that or the synchron motor is not fitted properly and is jumping the gear mechanism
  5. ianmcd

    Replacing a 25+ old Potterton boiler. Getting quotes for £3k+ to replace with combi.

    a 3 way valve as you call it can not stop all water circulation
  6. ianmcd

    Part Number for Ideal C30 Boiler

    try ideal 179050
  7. ianmcd

    Pipe slice prices

    Personally I would just pick them up when in screwfix or the like or order online, would never think of going into a shop just to buy a pipe slice, cant see your idea taking off
  8. ianmcd

    Replacing Potterton EP2002 and BG RS2 with Hive Active Heating and Hot Water thermostat

    No you dont , you have a Main HE A , they are not the same boiler
  9. ianmcd

    Replacing a Danfoss HPA2 (4 wire??) motorised valve

    just isolate the earth wire it isnt needed
  10. ianmcd

    Holes in plasterboard above boiler

    old ventillation if boiler is now room sealed just cover them up
  11. ianmcd

    New expansion vessel needed?

    Make sure you leave a drain point open while re-pressurising or no point in doing anything
  12. ianmcd

    F22 Dry error after power cut

    the problem will be with the zone valve(s)
  13. ianmcd

    Combi boiler making noise when running hot water

    well sorry but he is wrong
  14. ianmcd

    Drayton LP522 to Nest Heatlink

    yes that is correct and you will have to link out any existing thermostat
  15. ianmcd

    Combi boiler making noise when running hot water

    It isnt the heat exchanger, you need a proper gas engineer , your burner is resonating at low flame and the gas valve needs set up properly, not for a poke and go neewbie
  16. ianmcd

    Reluctance to do landlord cert

    Check his Gas Safe on the register, he may have boilers only, he will need CKR to do the hob
  17. ianmcd

    Swapped radiator now boiler won’t fire up

    unique to the Ri range of WB although i seem to remeber an ariston with similar
  18. ianmcd

    Swapped radiator now boiler won’t fire up

    At the top of the heat exchaanger there is a plastic bayonet fitting with a clear hose coming off, turn the bayonet until water comes out of the tube, be carefull the water may be extremely hot
  19. ianmcd

    Swapped radiator now boiler won’t fire up

    you have to bleed the main heat exchanger