Search results

  1. I

    Grant Vortex Combi boiler problems

    Thanks. I have checked the PRV and it is OK
  2. I

    Grant Vortex Combi boiler problems

    Thanks that is a good point. I had not allowed for the boiler capacity so I am right on the limit. So it looks like another exp vessel. Where be th best place to put it? The boiler is in a boiler room.
  3. I

    Grant Vortex Combi boiler problems

    The exp vessel pressure is still 1 bar so I think it is OK. It was new a year ago.
  4. I

    Grant Vortex Combi boiler problems

    Thanks for this Yes I de-pressurised the system. There are 11 radiators. I have calculated the volume when I installed the boiler as around 80 litres which should be within the Grant stated maximum of 128 litres. I notice that this is at expansion vessel charge of 1 bar and system...
  5. I

    Grant Vortex Combi boiler problems

    I checked the exp vessel pressure and it was 0.95bar. The system pressure was low again. I filled it to a preesure of 1 bar and fired the boiler. The pressure went up to 2bar+ and the PRV vented. It seems that there is not enough capacity to cope with the expansion of the fluid. Should...
  6. I

    Grant Vortex Combi boiler problems

    Thanks I will try that. I actually fitted anew one a year ago. The other was filled with water.
  7. I

    Grant Vortex Combi boiler problems

    Hi I have a Grant vortex 26 combi oil boiler. It is about 5 yrs old and has a couple of issues. 1. It doesn't seem to hold its pressure. I pressurise the system to 1bar but in a couple of days it reduces to almost zero but not low enough to trip the LP switch. There is a discharge from...