  1. D

    Biasi 28s No dhw No CH

    I had a boiler engineer but he couldn't fix first time round. He came round again after nee symptoms, changed the pump which i suspected to be problem and its all working!!
  2. D

    Biasi 28s No dhw No CH

    A biasi boiler, which was working fine few daya ago. Then suddenly no ch, and giving very hot water. Temp goes upto 70c Cleaned pump, changed diverter valve rubbers, cleaned heat exchanger. Pump cleaned, is working but feels hot. After cleaning secondary HE, the hot water is not working...
  3. D

    External Room Thermostat for BIASI 24 S

    Hi there , i am planning to install a room thermostat to biasi 24s boiler . However the loop/link in my boiler is connected at terminal 2 & 3. 1 Black - Neutral coming from boiler timer 2 Red - going to circuit 3 White - coming from boiler timer 4 Neutral - Live mains 5 Earth mains 6 Phase...
  4. D

    Combi Boiler in a new dormer extension {loft}

    Hello esteemed experts, I have been thinking about this and thought to get some advice here to see whether it offers any advantages if Boiler is fitted in the recent dormer extensions done. I have 2 dormers done { 2 houses converted into one } and I have nice brick wall in the middle...
  5. D

    KingSpan or Earthwool for Internal Wall (Solid) Insulation

    Thanks, appreciate your response and agree with you completely. I will ask him to go ahead with 50 ml kingspan with 3x2 's and leave 25 ml gap on wall side for Air flow. One more question, all wiring etc can stay in this 25 ml airflow area ?
  6. D

    Help with chimney breast removal

    I have full chimney removed for just 500. This was done in just 2 days.
  7. D

    KingSpan or Earthwool for Internal Wall (Solid) Insulation

    Hello experts, after a bit of advice as different people telling me different things :)) I have got all walls to bare bricks and plasterer ready for plaster boarding, however i am not able to make up my mind on either to use Kingspan or earthwool ? I have bought 50ml Kingspan cavity...
  8. D

    alternative to skip hire ?

    Hi there, skips are expensive, specially for the building materials/bricks waste .. I have heard there is alternative service where a collection lorry comes and take everything away but at a cheaper rate. just not sure what is it called or where to find them. Any idea ? thanks
  9. D

    how much to remove a load bearing wall

    I have recently got the similar work done, to remove a single load bearing wall ( supporting similar wall upstairs) between kitchen and living room. Only the wall removal and RSJ installation costed me £250 including cleaning. RSJ cost was extra £130 if that helps. the wall was 14 x 9 feet...
  10. D

    Chimney foundation question

    Hello there, thanks for looking at the post. I have a question on how to deal with this situation re the foundation after chimney removal. I have removed the entire chimney from top to bottom, i have dug up abt 10 inch down from my floor (room) but no sign of slab/concrete floor where the...
  11. Untitled

    Untitled

  12. Chimney base

    Chimney base

  13. D

    Staircase support question

    Thanks Noseall, We put 2 3x2 support to the landing joist and also rested them between the RSJ. Job well done so thanks for your prompt advice.
  14. D

    Staircase support question

    Hi There, thanks for looking, need a bit of advice on the staircase support. We are looking to get our wall between kitchen and living to be completely removed (single wall upstairs/downstairs - not in loft) and upper wall/floor to be supported by RSJ beam. While I was looking for Joist...
  15. Untitled

    Untitled

  16. Stairs

    Stairs

  17. D

    Fixing a Joist bearer to a brick wall

    Yes its for the brick wall. The span of horizontal joist is 14.8 feet including the 4 inch each into the side walls. the room height after dropping the ceiling would be around 2.8 meters. I had googled it and there are different size here , which one precisely ? link -...
  18. D

    Fixing a Joist bearer to a brick wall

    Hi Esteemed experts, I am lowering the ceiling which will be used for future loft conversion. I am planing to use the 200 x 50mm joist and planning to user a joist bearer to hang them from the front and back walls. I am planning to use similar size joist as a bearer ( bolted to the wall...
  19. D

    Do i need RSJ for lowering the ceiling?

    I own the above with more general DIY tools, i meant any specialist tool i might be missing ?