  1. G

    Rough install ??

    i know as I was there on the first fix . As the gas engineer ( I hold all electrical qualification also but only for surveying) I am anal when installing but it's evident when workmanship is lacking . Left exposed cables when stripping out with just the Mcb turned off and I was making them safe...
  2. G

    Rough install ??

    I think so , best of all it's a council contractor working for council in a private house , The shower keeps tripping out and unable to get the contractor back out so sent my sparky and he said its rough, said it should have a new board or at best facing where it's been cut for Mcb I need...
  3. G

    Rough install ??

    Hi all, Visually the install looks rough but to name few problems I don't no how it's been signed off The house was rewired 3 years ago and all is ok with this work but a extension has been completed and several new circuits upgraded onto the existing board * incorrect manufacture breakers on...
  4. G

    Worcester 28i greenstar. Possible pcb

    Hello, No instructions on site but am thinking it will be pcb but need some ohms reading to test as can't find any online I have a constant flashing light on the display. Cheers
  5. G

    Earth in wires

    I thought that this didn't comply with regs. I would say a lot of the older properties never do but from a maintenance point of view I always install a double insulated product but there is nothing protecting the cable.
  6. G

    Earth in wires

    I'm a heating engineer and if I was to wire the 10 way box and controls components I would always want to run a cable with the appropriate amount of cores including a earth, I always come across wires where they use the earth as a live wire . Can this be done Most of the controls are double...
  7. G

    City and guilds 2330

    I am looking at going collage to finish my electrical course , I already have 2330 level 2 but don't no what course I should be looking at now as there are so many to choose from and the numbers mean nothing to me Please advice
  8. G

    Halstead ace / no hot water

    Just a quick question regarding the diverter assembly on a halstead ace, as it has pressure sensing pipes, The pin does not activate the micro switch . would usually just replace the diverter to eliminate call backs but could there be a alternative reason on this model why the pin does not...
  9. G

    pendant in bathroom

    it is a normal pendant in zone 2
  10. G

    pendant in bathroom

    please can someone confirm if you can install a pendant in a bathroom.
  11. G

    LPG in a camper van

    thats fine, i will get a cp12 from this other company.
  12. G

    LPG in a camper van

    well the conversion company says they don't have to issue a certificate but they can get someone out to check it for a extra charge. i find it strange as you don't have to in a domestic property get it checked after a installation and u get a building certificate. just wanted it clarifying if i...
  13. G

    LPG in a camper van

    Don't the company that fitted the appliances have to provide a installation certificate like a house . i am thinking why would they say this is a extra charge, i suspect this company was not gas safe. which i would consider a illegal installation i no that each year i would need a new cp12...
  14. G

    LPG in a camper van

    Oh sorry forgot you can get a LPG covertion for the engine. My post relates to the two gas cookers that are inbuilt into the kitchen Cheers
  15. G

    LPG in a camper van

    I have had my van converted by a professional company. My insurance required a gas certificate, should the company that fitted it supplied the certificate. As they are saying this is a extra cost of £110 by another person. I suspect the conversion company are not gas safe and this is why the...
  16. G

    lpg in camper van

    Hello people. Need a little help, I am gas safe and do have LPG on my card but only touch once in a blue moon and avoid if possible. I have to give a cp12 for the insurance on a installation of two cookers and a small bottle (I think it is 7kg butane). These are connected on a single reg as...
  17. G

    gaps between spindals on banaster

    Thank you all for the replies. I did try elsewhere to get this infomation. I suppose i was ignorant with the bannister but i will say i will add extra spindles to tenant. To be honest they are playing there faces to remove it all together. What makes it worse this is my mate who was made...
  18. G

    gaps between spindals on banaster

    i rent out a property and the tenant as asked if they can remove the banister to open up the hall. i said this is not allowed due to safety reasons and they went on the internet and came at me with the gaps between the spindles are to wide, approx 210mm. i am under the impesion that new builds...
  19. G

    TRV's and Room Thermostats

    If the system has been installed in ther last 12months it should have two room stats and zoned. Is the installation registered, if so get a free inspection off gas safe.
  20. G

    fuse board makes

    thanks for your feedback