Search results

  1. J

    Worcester HighFlow 3.5 Heat Exchanger Replacement

    Has anybody replaced the heat exchanger on a Highflow 3.5 , Around 1994 (It serves both CH & DHW) I've identified mine is scaled up and am going to buy a replacement . Over the years i've replaced the divertor valve and pump no problem but was wondering if its a tricky job to do the exchanger?
  2. J

    Hiya I've sent you an Email..nothing to do with the Gloworm valve..its fine :) ...something else...

    Hiya I've sent you an Email..nothing to do with the Gloworm valve..its fine :) ...something else Thanks Adrian
  3. J

    glow worm parts

    These people helped me get my old Gloworm Backboiler up an running again after most said the parts were unobtainable http://www.sabre-spares.co.uk/
  4. J

    ok ..I have sent you an Email to that address... thanks

    ok ..I have sent you an Email to that address... thanks
  5. J

    olski I have sent you an E mail

    olski I have sent you an E mail
  6. J

    Can I get a gas valve for a Gloworm Capricorn 246N anywhere

    Agreed thats why if I can get one I'm getting a Corgi Guy to fit.. ----------------------------------------------------------------------------------- ..Its my conclusion the gas valve has failed based on... Pilot light working fine (Thats not brought me to the conclusion) Boiler can...
  7. J

    Can I get a gas valve for a Gloworm Capricorn 246N anywhere

    Thanks for that Gasman.. The plate on my boiler says Capricorn 246N I notice a few places on the net appear to be selling valves for "Capricorn 246" and list Glowworm part number 203328 would this be the correct valve for mine?? As you probably know the Capricorn 246N is a combined...
  8. J

    Can I get a gas valve for a Gloworm Capricorn 246N anywhere

    Old Back boiler I know and will need replacing soon but would like to keep it going another year.. Have identified that gas valve has failed but been told obsolete...Is there anywhere that I can get one from and then get a CORGI guy to fit for me.. Many thanks
  9. J

    Baby inquest told of water fault

    An absolute tragedy ... Can anyone take me through from a technical point of view what happened? I'm guessing it was a copper tank with an electrical immersion heater?..The temp stat on the copper tank failed?..The water then started to boil and then boiled up through the vent pipe to the...
  10. J

    pilot jet/thermocoupler on Old Glow-worm Capricorn boiler

    I need to get to the thermocoupler and check the pilot jet for dirt/blockage on this old back boiler.. I can't fathom how to remove the front gas fire to get to the pilot jet and the thermocoupler it looks is a really inaccessible place...tucked right at the bottom left of the back of the...
  11. J

    Two F & E Tanks in loft is this possible

    Yes I reckon they had limited space when fitted ..so I think thats why I have two!..thanks everyone!
  12. J

    Ball valve, Part 1, Part 2, Torbeck or what?

    We were told on our C&G course (which of course means I know nothing)..that whilst you can still buy part 1..they are illegal to fit...
  13. J

    Two F & E Tanks in loft is this possible

    we have only the one boiler..its weird never seen this before....
  14. J

    Two F & E Tanks in loft is this possible

    Just got up in the loft of our house for first time to find out what is causing damp patch on ceiling.. There are three water tanks..A large one which I assume is the hot water supply gravity fed.. There are two other small tanks side by side..I was expecting one..Are they both F& E...
  15. J

    No Hot water flow coming out of kitchen mixer tap

    Hi its an old tap been in place many years no probs before
  16. J

    No Hot water flow coming out of kitchen mixer tap

    Hi The hot water coming out of my kitchen mixer tap has stopped flowing and is now just a trickle.. hot water is working fine in the upstairs bathroom. I don't have any central heating and the hot water comes out of a copper cylinder immersion heater upstairs.. Any ideas on what might...
  17. J

    Conservatory Heating..Radiator or underfloor heating

    Thee is a bit of building/possible plumbing/possible electrics so hopefully this is the best place for this post I'm currently building a conservatory and am undecided on how to heat it..I've got the option of plumbing in a radiator off the existing system or installing underfloor electric...
  18. J

    Conservatory floor height and what do with door sills advice

    I'm shortly to lay the concrete slab for my conservatory.. The access to the conservatory from the house are through two sets of upvc doors on my property which have upvc door sills outside My question is what height do people normally build a conseravatory floor to..is it the same height as...
  19. J

    What are the regs on burying cable in a concrete base

    i'm just about to start building a conservatory and intend taking the mains electricity for it off an existing socket in my house extending a ring..For a number of reasons the most sensible way of running the cables in the conservatory would be in the floor base whilst i'm building it as this...
Back