Search results

  1. darenfriday

    Shower model? (Hansgrohe)

    The red button doesn't pop out either, hasn't for a long time. Stuck in. Never really been an issue but annoying. Related?
  2. darenfriday

    Shower model? (Hansgrohe)

    Hey DIYNotters Our shower doesn't get any cooler when I turn down the tap. Can anybody tell me the model? I have Googled and Googled I guess I may need a new cartridge but not sure. Thanks Daren
  3. darenfriday

    Hive Installer in Kent

    Ha ha ha. I hadnt set the timer on the Hive app for the hot water! Doh!
  4. darenfriday

    Hive Installer in Kent

    Gents... Whoops This morning my better half has no hot water in the shower. The rads are all toasty, the house is lovely but the taps run cold. I have a MegaFlo, so I guess thats fully pumped. In the airing cupboard there are two small motorised valves and one large white motored valve. The...
  5. darenfriday

    Hive Installer in Kent

    I did it last night and it's all working well. Put the red link wire from the old timer in the bin and terminated the blue wire into a choc bloc. Joined the wires from the thermostat, buried them back into the wall and stuck the new fancy thermostat over the hole. Thank you Gents for your vital...
  6. darenfriday

    Hive Installer in Kent

    Hey Stem Thank you, all good news then I do have a wall stat which I would rather remove altogether. Originally it was a 3 wire old style which I replaced with a Honeywell digital thing with just two wires. Ill take it off tonight to have nose at the wires. Will those two wires go back to...
  7. darenfriday

    Hive Installer in Kent

    Hey Ian I've powered down, checked the fuse is 3amps and popped the front off the existing Potterton EP3002 and it looks like a dual channel Hive is a direct replacement. The PINs are virtually the same. The Hive Receiver doesn't have pin 5 like the Potterton but it's just linked back to live...
  8. darenfriday

    Hive Installer in Kent

    Hello All We have a Potterton Suprima 60L with an external MegaFlo so sealed system. The thermostat is on the wall in the hall and the time r is on the wall in the kitchen. Can I have a Hive system? Anybody know a Kent installer rated? Thanks Daren
  9. darenfriday

    Potterton Suprima 60L PCB version?

    Thank you for all your answers
  10. darenfriday

    Potterton Suprima 60L PCB version?

    Another question Ian... We have a Megaflo tank upstairs so will we need a SYSTEM or STANDARD boiler?
  11. darenfriday

    Potterton Suprima 60L PCB version?

    Looks square to me. Good or bad? Can you suggest a replacement that might have similar dimensions that would fit in the same cupboard? If I have to replace anytime in anger I'd like a prepared quote/agreement.
  12. darenfriday

    Potterton Suprima 60L PCB version?

    Hey Gents and Gentettes We have a Potterton Suprima 60L since the house was built in 2002 (19 years old now). We did have boiler cover from British Gas and they did at some point replace the PCB (2008) while we had an issue but I don't think it was the problem. How do I know if I have the...
  13. darenfriday

    replacement for potterton ep2002 programmer

    Will the Honeywell acctuator fit on the Myson valve head or do I have to replace the entire valve?
  14. darenfriday

    replacement for potterton ep2002 programmer

    Yes, if I turn off the slider the CH goes off no problem. The valve is a Myson Power Extra MPE228 and yes it does resist when I push without the power but I rewired the stat because I thought I'd got it wrong and now I've blown the valve drive.
  15. darenfriday

    replacement for potterton ep2002 programmer

    Hi I tried 2 other room stats already and get exactly the same fault
  16. darenfriday

    replacement for potterton ep2002 programmer

    I have an EP3002. What were the symptons of your faulty CH. Everytime the heating times on it fires constantly regardless of the wall room stat. Does that sound familiar? Thanks Daren
  17. darenfriday

    Replacing Honeywell T6360b with CM901 - problem

    Hi, I hope you are still listening to this thread... I am using the same stat CM901 and have tried others and get exactly the same fault. When the timer turns on the heating it fires up regardless of the stat setting. I thought I'd wired the stat wrong so I rewired and now I think I've...
Back
Top