  1. N

    Patio grout 'dust'

    Hi folks I've looked through and searched but can't find anyone with this issue in the past. 2 years ago I laid a patio and grouted using brush in silicon grout. 2 years in I'm still gettibg a fair amount of dust coming off the grout meaning I have to sweep the patio regularly to get rid if...
  2. N

    neff cooker bulb tripping breakers

    I've also been using a slightly lower wattage bulb which shouldn't make any difference.
  3. N

    neff cooker bulb tripping breakers

    Hi John. It was the 32A MCB.
  4. N

    neff cooker bulb tripping breakers

    Hi guys. I have a neff oven that blew a bulb and tripped the breaker. I've tried replacing the bulb twice and each time it's immediately blown the bulb and tripped the breaker again. Any ideas? Cheers[/list]
  5. N

    soft rubber seal - what is it called?

    Thanks guys. Neithee ofbyou have answered the question. Its not a fibre washer, more a soft rubbber seal. The chrome pipe leading from the tap is slightly larger in diameter than the 15mm copper. The opening is slightly tapered in some way.. The copper then sits just inside the taper with the...
  6. N

    soft rubber seal - what is it called?

    Hi guys I have a sink rocker tap where ive changed the main core. To take it apart I had to take the whole tap off as it was stuck together over time. Under the sink have about 4 inches of threaded tap column before it meets the copper pipe. When I took it apart there was a soft white seal...
  7. N

    17th Ed Training - I'm confused!!

    Thanks guys I passed an EAL Domestic Installers course in 2003 which I was assured by NIC was 2381 equivalent. I will double check with them to make sure what this means for 2382. Confusion and opinion reigns on ambiguous statements from the authorities and bodies as usual. Thanks again
  8. N

    17th Ed Training - I'm confused!!

    Well spotted Gary Typo - It should have read 2382
  9. N

    17th Ed Training - I'm confused!!

    Do I need a new certification? Do I need any further training? What training do I need? I have read an NICEIC publication that says .... "Whether you require formal training and a recognized qualification or just want an overview of the changes, we have a range of solutions." Well do I...
  10. N

    New sockets/wiring in kitchen

    Easilly accessible - in the cupboard, open the door!!! No further than 2M - In the cupboard above the cooker. My kitchen is only 2.5m from floor to ceiling!!
  11. N

    New flat test certificate

    How does that work then? Surely you're either a competent person with an NIC card or not?
  12. N

    New sockets/wiring in kitchen

    1. Connect the cables using choc block and tape and extend to the new socket assuming vertical cable run is observed. Keep the old socket box in place. Put a blanking plate over the old socket box. Regs says the connection should be easilly accessible so strictly speaking there should be access...
  13. N

    Single to Double Ring Main Circuit Conversion?

    Access should be possible via the floorboards on th first floor. To split the circuits you firstly need to ascertain what sequence your sockets are cabled in. i.e. if the ground floor are on the front end of the ring and the first floor on the back end of the ring. Unfortunately knowing how a...
  14. N

    Kitchen Ring Load

    Slight difference of opinio guys. Hopefully you can help settle. Firstly we are both PartP and NIC but have a difference of opinion as to how bext to deal with this Kitchen re-fit. New 32A kitchen ring including 4 sockets, 3 integral appliances (Microwave, Washer/dryer, Dishwasher) plus a...
  15. N

    Safety Certificate - Rented property

    The letting agent has asked for and 'Electrical Safety' certificate. As there is no legal requirement to provide certificates for electrical safety what is he asking for? I assume as there is no legal requirement there is no standard format either? Cheers
  16. N

    Immersion heater cable

    2.5mm T/E from the CU to the FCU but no longer than 30m. From the FCU to the heater I have read somehwre but can't find it that heat resistant cable is necessary but I don't believe it is in the Regs so may have just been a recommendation. If that is the case then 13a T/E Flex will do the...
  17. N

    Depth of chasing

    Can someone settle me an argument regarding a job we start next week. I have an NIC leckie starting a job for me next week and he has said that according to 16th edition and the OSG there is a stipulated depth of chasing inside the zones or the cable has to be capped. i.e. vertical and...
  18. N

    Towerstat RF wiring

    Guys Subject - Baxi Combi 105HE I'm not a CH expert but I am part Pd. I need some help with the wiring on a Towerstat RF Thermostat. At the moment the boiler (Baxi Combi) has no roomstat, only a fused switch for on and off and an integral time clock. The wiring in the boiler has...
  19. N

    Towerstat RF wiring

    They all look the same to me.........! Only joking........ Baxi Combi 105HE
  20. N

    Towerstat RF wiring

    Guys I'm not a CH expert but I am part Pd. I need some help with the wiring on a Towerstat RF Thermostat. At the moment the boiler (Baxi Combi) has no roomstat, only a fused switch for on and off and an integral time clock. The wiring in the boiler has 5 terminals. 1. Live, 2. Neutral...