  1. B

    Problem with Gloworm Energy Saver 30e

    No there is know lockout light alight.
  2. B

    Problem with Gloworm Energy Saver 30e

    When I say I can hear the gas I mean I hear the gas valve open and after about 4 seconds it closes again.
  3. B

    Problem with Gloworm Energy Saver 30e

    Hi everyone, Got a Gloworm Energy saver 30e gas condensing boiler which doesn't work. Sometimes it works and other times it doesn't. You hear the gas valve open and gas come through and then it quickly closes. Sometimes when it does work it goes with a rush and a bang. I am reluctant...
  4. B

    Problem with Gloworm Energy Saver 30e

    Hi everyone, Got a Gloworm Energy saver 30e gas condensing boiler which doesn't work. Sometimes it works and other times it doesn't. You hear the gas valve open and gas come through and then it quickly closes. Sometimes when it does work it goes with a rush and a bang. I am...
  5. B

    Problem with Suprima 50

    I am looking for your years of combined knowledge and wisdom. I have been called into to have a look at a Potterton Suprima 50 that locks out after a week. I have checked all controls, wiring etc. Water in system, that side is fine. What happens is, the red light flashes, which points...
  6. B

    Problem with British Gas Boiler RD1

    Thanks for all your help, sorry I was a bit of last night, as you say one of those days. I have put harness on order, should be with me tomorrow. Fingers crossed. Thanks again
  7. B

    Problem with British Gas Boiler RD1

    Why are you being so aggressive, I am after help not more headaches. Don't worry I will lay awake and work it out myself!!
  8. B

    Problem with British Gas Boiler RD1

    I am a Corgi Engineer, have been for 20 years. I have followed instructions fault finding charts and made a judgment on what the results of the multi meter and my experience told me. Do you think there is a chance I have been sold a faulty pcb? I am sure I am not the only Engineer out...
  9. B

    Problem with British Gas Boiler RD1

    Good evening everyone, I desperately need some advice. I have been called into have a look at a boiler a (british gas RD1) which as far as I can tell is basically the same as the Ideal Classic. When you turn the boiler on led 3 and 4 come on for about a second than go to led 3 flashing...
  10. B

    Old Trevi Therm instructions

    Hi everbody, been called in to have a look at an old Trevi Therm exposed shower that will not quite turn of. Problem is customer can't find instructions with list of spares and diagrams etc. Has anyone got one they could scan and email me or tell me link to a website, I have done a few...
  11. B

    Inline shower pump

    Cheers, I knew you wouldn't let me down. Matt
  12. B

    Inline shower pump

    Hi everyone, does anyone know where you can buy an inline shower pump that fits between the hose on a bath mixer tap and boosts the water when the shower is in use. Newteam and shower force use to make them but they seemed to have stopped. The pump fits to the wall above the bath. Might be...
  13. B

    Flow-Sensors on Gloworm CXI Boilers

    Hi everyone, has anyone out there had any problems with the flow sensor leaking on Glow Worm cxi Boilers. I have fitted 5 over the last 3 years and two of them have developed this fault, a leaking flow sensor. One of those O'ring and circlip jobs. Am I just unlucky is this a fault with...
  14. B

    Joining onto black alcyethene pipe.

    I think you are out of order calling it a bodge, it's whats was done 30 - 40 years ago, who's to say that our speed fit culture today will not be classed as a bodge job in 50 years time. At the time it is acceptable and thats good enough for me. You are not talking to a 3 month college...
  15. B

    Joining onto black alcyethene pipe.

    Good news, the fracture was right by the brass fitting, so was able to knock the cone on a bit more and cut the pipe back and remake the joint. Sorrted. Matt - NigF, yes I am in East Sussex and I always do thing properly. Spelling is my downfall.
  16. B

    Joining onto black alcyethene pipe.

    Hi everyone, a few months ago I changed a hotwater cylinder that an old plastic black aclyethene pipe as the cold feed. Had a brass fitting compression fitting on the end so just joined back on, plenety of boss white and hope for the best. Last night had a phone call to say the pipe had...
  17. B

    Baxi and Heat Team nightmare

    New boiler fitted, sorted. Everyones happy.
  18. B

    Changing Indirect Hot Water Cylinder

    I always put a couple of feet of 15 copper tube in the end of the hose, then you can feel it touch the bottom, otherwise your hose may coil around and float to the top. Top tip, I reckon. I think airlocks are what sorts the men from the boys. You can't learn how to clear an airlock at...
  19. B

    Baxi and Heat Team nightmare

    What a cock up, new heat exchanger and flue hood sent down, sub-contactor refitted, new one had a crack in it. Damaged in transit. Baxi are now sending a new boiler to my home first thing Tuesday morning and paying me to fit it. Why couldn't they have done that a week ago. Saved me 30...