  1. J

    Photo's of my CU change

    If its covered by a 30mA RCBO then isnt the max efli 1666 ? The neutral numbers dont correspond with earths or lives
  2. J

    3 Phase TT supply and RCD

    Think my boss found a hager double insulated 3 phase board, but if cant find one, like u say external RCD.... seems this would perhaps be best anyway as pointed out by plugwash, RCBOs wont stop a neutral fault... so maybe external rcd to supply 3x double insulated single phase boards (maybe...
  3. J

    3 Phase TT supply and RCD

    Hi, have problem Currently a metal DB with failing RCD installed 3 phase TT supply Need to change DB for Double insulated IP rated with 100A 100mA TD RCD Problem is .... a time delay RCD trips with 0.13s-0.5s but under 17th edition, it must trip 0.07secs as i understand from Table 41.1...
  4. J

    is this a reliable earth connection?

    ive seen a bit of MICC, still doesnt look like it to me, but if u say it is then ill believe .... to be sure, just try bend the cores a little, if its stiff then they are solid conductors, so sure to be MICC
  5. J

    is this a reliable earth connection?

    they look like vir's or rubber cables going into copper conduits with rubber 'cable protectors' on the end anyway, what ever it is there is probably joins and its heavily oxidised and possibly corroded in places
  6. J

    is this a reliable earth connection?

    that doesnt look like MICC ... if it is then the cores are single insulated which needs to be enclosed ?
  7. J

    ELCB fitted in a CU

    Should be able to, is it external to the fuse board ?
  8. J

    Split load with two RCDs

    if you are only planning to use circuits covered by 2x30mA RCDs, you dont need a 100mA RCD, just use a normal isolator ?
  9. J

    Split load with two RCDs

    the MK solution sounds good .... i think it works out cheeper to buy another "split load board" rather than the split load kits ? (not sure on inet prices though) take it that some circuits will not be on the 30mA RCDs and will only be on the 100mA RCD .... so u will actually have 3 banks of...
  10. J

    Split load with two RCDs

    sorry i mean, whats Dartlec intending to use it for
  11. J

    Split load with two RCDs

    Whats the 100mA RCD for ?
  12. J

    Electric shock treatment

    lol u made whole new account so u could say that .... nordski :lol:
  13. J

    Earthing rod for TT system

    doesnt have to be 10mm depends how its protected... but yeah this sounds like crap .... why dont u ask your mates mate how to run TT earth ... surely he would know delete his account ... he is beyond help ?
  14. J

    2391 result

    8 months for certs to come :lol:
  15. J

    The looks you get!!

    ye thats what i said or was trying to :P
  16. J

    The looks you get!!

    dont have regs .... whats it about ? lighting without CPC ?
  17. J

    The looks you get!!

    not if the cables test out ok, no
  18. J

    Bathroom Ceiling Extractor

    if u cant get into the roof space above due to person aboves flooring their isnt much u can do... install ducting in your kitchen and box it in :( doesnt look amazing but not sure of any other way really u need someone to come and have a look at it, local builder or someone ... they can...
  19. J

    Spark wants money in advance

    just because they owe you doesnt mean you'll get it though if u take them to court over it .... all they have to do it write a cheque for £1 and then you have to restart the whole court process, which will cost u more than its worth in long run what happens when u 'quit' a job before...
  20. J

    The looks you get!!

    in terms of safety yes, in terms of law apparently not... when we went to 17th edition seminar a bloke told us that "u test to whats safe, not to current standards or you will forever be going back" ..... not sure what new regs are brought out for if its not to raise safety but hey ..