Search results

  1. S

    External insulation coating

    My daughters recently acquired 1900's brick built semi has external insulation mainly on the large gable end. Unfortunately it wasn't picked up on the survey that the coating that covers the insulation is bubbling up in many places. My plan is to strip off all the old coating and re coat but...
  2. S

    Homeboost

    I'm on a shared supply (1930's semi) and despite my complaints to Yorkshire Water about low pressure when my neighbour is using the water supply they refuse to do anything about it. The have tested the flow rate which they say meets minimum requirements but the test was carried out when no...
  3. S

    Loss of mains water pressure

    Little stones were in the stopcock and had also blocked the inlet gauze on the pcv. Thanks for the input.
  4. S

    Loss of mains water pressure

    That's what I'm thinking, either rubber washer come off stopcock or blockage in the prv. Do prv's have a filter.
  5. S

    Loss of mains water pressure

    Daughters newbuild house had a leak in the upstairs bathroom today, no isolator valves on the offending taps and stopcock not fully shutting off so turned off at the water meter stopcock in the street. On turning both back on the gauge on the pressure reducing valve eventually goes upto 4bar but...
  6. S

    Old boiler replacement

    With the rising cost of gas is it worth replacing my 1989 Ideal mexico 2. The boiler has been very reliable having only 2 issues gas valve and pilot light thermo couple in all that time so I'm reluctant to get rid. Everyone I know with a combi has had expensive trouble with there combi's but...
  7. S

    3rd bedroom extension over carport

    Thanks Woody, yeah was looking at this last night https://www.wickes.co.uk/STS-Construction-Board-1200-x-800-x-12mm/p/225437 is that ok or is there a better alternative ideally 8' x 4'.
  8. S

    3rd bedroom extension over carport

    My 1930's semi 3rd bedroom was extended back in the 70's, the extension has a carport underneath. The underside of the extension floor joists /carport ceiling has what I believe to be asbestos sheet attached with no insulation. What's the modern alternative in this types of installation today, I...
  9. S

    CH not always firing up

    Thanks will have it serviced and hopefully only the solenoid coil needs changing.
  10. S

    CH not always firing up

    I like to be armed with a bit of knowledge before calling in the professionals as I have been caught out by some unscrupulous tradesmen in the past. My boilers (a Ideal Mexico Super 2 RS60 serviced 2 years ago) pilot light was lit but main burner wasn't firing up despite controls calling for...
  11. S

    Ideal mexico super 2 RS60 issue

    My old Ideal Mexico super 2 RS60 has developed an issue where the heating/hot water has become intermittent. I've tested power to the gas valves solenoid which is a steady 248v ac when the controls are calling for heat but the solenoid doesn't seem to have enough pull to suck in the plunger. So...
  12. S

    Warped cupboard doors

    No finish on them yet, I let the wood fully dry out in my loft turning them every couple of days. The door was straight after glue had set and they've been stored in my spare bedroom for a week or so before the were offered up. I've gone a bit more than 6mm and after reading an up added...
  13. S

    Warped cupboard doors

    Made from softwood 70mm x 38mm, mortice and tenon joints with 9mm ply slotted into routed grooves The door in question measures 1100mm x 380mm.
  14. S

    Warped cupboard doors

    I recently made some cupboard door's to fit a new airing cupboard frame I also made. On fitting the doors I annoyingly noticed one of them has twisted about 7mm, the other's have remained true. I currently have the door clamped to a bench to try and reverse the bend, is there anymore I can do to...
  15. S

    Mortice& tenon depth and widths

    It's just an airing cupboard at the top of my landing. There is some downward load from the cold water storage tank in the loft space above. that is currently supported by an accro on one side and the wall on the other hence I feel the need for a 70mm post. Just want to make it as strong as...
  16. S

    Mortice& tenon depth and widths

    Any rules of thumb how deep a mortice hole should be. I gather the tenon should be a 1/3 of the width of the timber so on a piece of wood 42mm deep a 14mm tenon. How deep should the mortice hole be. The posts where the mortices will be cut are 70mm square and the tenon timber is 68mm x 42mm. I...
  17. S

    15mm Hot pipes

    Thank's everyone some good points for and against there, but I'm still in 2 minds. A bit more info, system is gravity fed and it's about 10m run to the basin. I'll make sure I buy a mixer tap suitable for gravity fed
  18. S

    15mm Hot pipes

    About to re fit en suite and the current supply to the basin is in 15mm copper, should I change the pipe to 22mm for better flow. The flow and pressure to the single hot tap is ok but I will be fitting a mixer.
  19. S

    Best diy wired alarm system under £200

    Just needed to know about alarms not to be lectured on my security you obviously don't read my posts properly before you reply.
  20. S

    Best diy wired alarm system under £200

    No worry is not the car, cars insured, the worry is my family if thieves break in to steal the car keys. Car fully alarmed etc security lights, gates on drive, keys now kept in draw. Only lived here a couple of years, nice area, very quite never got round to fitting an alarm hence my questions.
Back