  1. R

    Energy monitor clamp behavior!? (Looping live thru clamp)

    He has only taken the Line through that part of the circuit!!
  2. R

    Switch wiring.

    Did you note how the switch was connected before? Can you post some pics?
  3. R

    Loss Of Supply - (PIC)

    Yuk!
  4. R

    50 Hz white goods on 60 Hz supply

    The electronics in these appliances will also behave differently at higher frequency.
  5. R

    Can I veto PAT testing

    PUWER
  6. R

    Terminal Block Current Question

    My inference was that we do not initially choose conductors based upon their surface area only by their csa.
  7. R

    Terminal Block Current Question

    It is not the surface area of the conductor that determines it's current carrying capacity but it's cross sectional area. Skin effect can be ignored in the most part for sizes smaller than 16mm² at 50Hz.
  8. R

    Fluorescent light problems

    You need to test the voltage at the light. If 230/240v present then more than likely a failed ballast if you have changed the lamp and starter (unless one of those two replacements are faulty)
  9. R

    The Super Fuse

    I just wonder after shelling out over £5K for a mains cable how easy it would be to get your money back if you weren't completely satisfied?
  10. R

    Quick question

    You must have a very narrow-minded view of life
  11. R

    Quick question

    I can't believe the question is even being asked! :wink:
  12. R

    Hospital Wetroom

    Stat looks more like a capillary type than electrical.
  13. R

    24WAYS -3 DAYS

    Was it just the board or were there any remedials (bonding etc)? What hours did they work per day? Were all of the circuits tested before and then all of the RCBOs tested afterwards? Was there straightforward access or was it awkward?
  14. R

    PAT (testing)

    Back to the OP. I personally would fail a PC whose cover was off/loose in a normal environment (assuming no repairs had been agreed) due to the fact that I'd be wondering why it was off in the first place eg was someone non-competent fiddling or having a bad day and given it a kick? If the PC...
  15. R

    Power circuit design

    Yes, apart from being subject to any adverse installation conditions, then a 20A mcb should be fine (or even 25A if you can obtain one) If you suspect there are more junction boxes then I really would want to be checking the connections in them though.
  16. R

    Main Cable in Industrial Unit

    Are you sure that the post is not going to be in the way of any of the electrical equipment for adequate access/servicing space?
  17. R

    Best electric heater to warm a room (sensible and practical)

    Fan heaters are the most effective
  18. R

    Overloaded circuit - trips RCD

    Overload is unlikely with the appliances you refer to. More likely a substantial, intermittent fault if it is only an mcb tripping. If it is an RCD then it could be an intermittent earth fault or an accumulation of normal leakages and an over-sensitive RCD.
  19. R

    What you make of this...

    It is and was against regulations to identify phases in SP circuits as anything other than red/brown, regardless of which phase they are actually on. The only exception used to be SP sub-main circuits.
  20. R

    bulbs constantly blow in one room only

    If it is the last light on the circuit then there could be a loose feed connection to that light from an adjacent room's light. I suggest checking all connections in the circuit. Also, is there any type of shade on this light which would impede the heat escaping from the lamp?