  1. davelx

    Why isn't 3-core cable the standard for lighting circuits?

    Just connect the spare core to the earth terminal at each end (as well as the (hopefully G/Y sleeved) earth core). Then it's there if you need it in the future.
  2. davelx

    Oh dear! (Shoddy electical work) (Ed.)

    Thing is, if you don't know and you don't know that you don't know. I wonder if it's on an RCD protected circuit.
  3. davelx

    Bungalow 'ringing' after fibre installed in street

    Fibre is correct in the UK.
  4. davelx

    lighting circuit keeps tripping (Ed.)

    Does your phone's camera not have a flash or fill light function?
  5. davelx

    Unknown Markings on road / pavement

    When they did that down my road it was for a rainwater gully. Arrow indicated direction of flow to the sewer.
  6. davelx

    Adding a suitable heater to a tiny toilet for my mum

    Oil filled radiator with timer. You'll need to install a 13A socket in the toilet, you can't run it from a lighting circuit. It does not require an electrician to do this, it is well within the scope of a competent DIYer. Where is the nearest 13A outlet? It may be possible to take a spur from...
  7. davelx

    EICR Unsatisfactory - FTB

    If the seller has read this forum he'll tell you that the asking price takes into account the condition of the electrical installation, so no reduction, as often advised here.
  8. davelx

    5 gang light switch!

    Always better to leave colours to the wife!
  9. davelx

    Your opinion on the safety and legality of this board please.

    There are ways to extend a busbar - that's not one of them, it may not be making good contact in the terminals and will be physically stressing the devices. Devices not aligned and busbar not fully inserted. Where's the busbar cover? Given that BG busbars are not exactly expensive and are...
  10. davelx

    Which saw to cut and trim kitchen plinths?

    Hire a portable table saw with a suitably fine blade?
  11. davelx

    Loop electrics changed by national grid but left with consumer unit issues?

    And nothing that was done could change the power going through the consumer unit as all the DNO work would (should) have been on their side of the meter. Uprating the DNO fuse will not make one iota of difference to the power being drawn by the installation. Something else must be going on...
  12. davelx

    RCD FCU tripped when fitted to CH, likely reasons?

    The UPS is a separate unit from your GTI? A proper online UPS does double conversion - AC - > DC - > AC so the output waveforms and characteristics are totally separate from the mains input. So whether the input comes from the grid or from your GTI in inverting mode is nether here nor there -...
  13. davelx

    RCD FCU tripped when fitted to CH, likely reasons?

    What type of UPS? True sine-wave?
  14. davelx

    Do i need to rewire or upgrade consumer unit for EICR??

    I wouldn't know, I don't do domestic. It depends on many things, you need to get some quotes. Someone else may have a better idea
  15. davelx

    Do i need to rewire or upgrade consumer unit for EICR??

    Wrong way round. EICR first. Get any C1 & C2s fixed ( not necessarily by the same electrician....get quotes). Keep original EICR together with EICs from the remedial work. Job done.
  16. davelx

    Obtaining a ECS Gold Card help

    Have you looked on the ecscard website? https://www.ecscard.org.uk/content/Health,-Safety-Environmental-Assessment
  17. davelx

    Double Socket

    Do NOT twist them. Do it as per the photo, which is the correct method.
  18. davelx

    Cable size for extension?

    Note that those converters are fused, so max load across all three outlets is 13A
  19. davelx

    Annoying Driving Habits...

    No, never looked at this topic before.
  20. davelx

    Annoying Driving Habits...

    Oncoming drivers signalling that they are turning (to their) left who then pull across into my lane before turning as they are too lazy/stupid to turn their wheel faster/ to full lock.