Search results

  1. BDL

    Blue Waffles Disease

    Anyone seen this blue waffle stuff? Google blue waffles disease and you may be surprised. (Not before eating though) :P or try this http://www.bluewafflesdisease.co.uk Ahh, just google it- this can't be real? Can it? :lol: :lol: :lol: :shock: :shock: :shock:
  2. BDL

    Surveillance Company

    Nah, not Prince Willy. Bless him. Too late now. I'll fill you in once I get the report.
  3. BDL

    Surveillance Company

    Hmmm, pretty impressed so far. £500.00 fixed fee and they are on the job tomorrow. Still feel awful, but I do have genuine concerns. I figure that at least one way or the other I will know for sure. www.discreetsurveillance.co.uk if anyone is interested. Hope for your sakes you never...
  4. BDL

    ideal response se will not fire up

    The Response se is a condensing Response. A Minimiser heat exchanger with a Honeywell/Grindfoss water set. Code 4-04 is just a generic lockout, the 2nd code that follows is the cause. 9-12 is the low water pressure switch. Concurrent with your comment the boiler loses pressure. Find out...
  5. BDL

    Surveillance Company

    Hi guys, Random question I know. Would you consider using a surveillance company if you suspected your other half was up to no good? I.E having it off with someone else? Think I am being paranoid, but for the sake of sanity and to find out once and for all I have done it today. A...
  6. BDL

    Boiler breakdown Baxi courses

    Dartford centre is ok. I did a day with the duotec last year. Bored the living hell out of me. And I upset the trainer for talking cobblers. Apparently onboard fault diagnostics is wasted on anyone other than manufacturer engineers.
  7. BDL

    Boiler breakdown Baxi courses

    http://cgi.ebay.co.uk/ws/eBayISAPI.dll?ViewItem&item=130509369104&ssPageName=STRK:MESELX:IT What more would you want? Training and support?
  8. BDL

    Advice on how to become a Corgi Plumber?

    http://www.heatingdiagnostics.org.uk sorted.
  9. BDL

    Ideal Logic+ 30 - Constant NO WATER FLOW LOCKOUT

    Just unscrew the Trv head and leave it off, if the boiler does not lock out then BG need to sort. You cannot have full TRV'S, no bypass and no roomstat. BG MUST install a roomstat, and the radiator adjacent must not have a TRV. It really trashes my mind when BG do this. Total jokers.
  10. BDL

    Ideal Logic+ 30 - Constant NO WATER FLOW LOCKOUT

    Full Trv's? No uncontrolled? Sorry just saw that in your post. Where is your roomstat located? Unscrew the head of the TRV and test.
  11. BDL

    Ideal Logic+ 30 - Constant NO WATER FLOW LOCKOUT

    I presume they commissioned the thing correctly? I would interested in what temperature differential they got on the he4ating flow and returns with the Trv's turned off? Do you have an uncontrolled radiator adjacent to your roomstat? You do have a roomstat? Do me a favour? Take a Trv head...
  12. BDL

    Potterton Netaheat 16-22

    Most of these have asbestos content, seals worn, positive fanned. Do yourself a favour and start saving for a new boiler. Def. DONT OPEN IT AND MAKE SURE THE ENGINEER TESTS IT BEFORE LEAVING. :-)
  13. BDL

    Noisy boiler problem

    Ring Ideals, explain to them the problem and ask them to fit a flowswitch to your Dhw side. It is available as an extra and the problem will be solved. (Unless you have a leak somewhere, which I doubt because it will fire every 90secs or so). Hope that helps.
  14. BDL

    HELP - 3million gallons of water gone through my watermeter!

    Easy one to sort. Many utilities are under extreme pressure to reduce their leakage rates by Ofwat. A leak of this size should be of major importance to them. Thames Water and many others are using a bit of kit that attaches to the meter in order to remotely observe any leakages. See...
  15. BDL

    Drayton Valve

    Thnx Clf-Gas. Saw that, but need the actuator too. They have quoted a 7 day delivery time.
  16. BDL

    Drayton Valve

    Any idea where I can get a Drayton Tav6(1 inch) and actuator off the shelf today? Usual suppliers look at me blankly.
  17. BDL

    DHW light flashing

    Flashing dhw led indicates that the thermister is faulty. (Situated on dhw pipe at the bottom rear of the heat exchanger). Might be worth removing it and giving it a good clean. If you need hot water over chtg then just swap the 2 thermisters until you can get it replaced. You have...
  18. BDL

    Combination (of) boiler faults

    Intermittent dhw flowswitch sticking. Bet if you take it out and stick a u guage tube into the pipe you will find a small black o ring or a piece of debris.
  19. BDL

    Ideal response 120 boilers - ignition problems

    Presuming that there is actually pressure in the boiler your wtr pressure switch is blocked. Drain boiler from drain nipple on isolation valve. Remove 3 connections on switch (Turn power off 1st). Unscrew switch clear hole in switch (gently) and also hole on the pipe. Refit. Reattach...
  20. BDL

    Ideal response 120 boilers - ignition problems

    I reckon you have a blocked water pressure switch or stat tripped (bottom of boiler red button) or fuse f4a has blown on pcb 40. Wtr press switch- Check for continuity between pink and brown wire to overheat stat. If no continuity remove switch and clean hole. If fuse f4a has blown...