  1. P

    Close-coupled pan.

    Could you use a swan neck connector it would get you about 3" back or maybe a flexible one from plumb centre they are soft and you could gain more??
  2. P

    No working radiators

    Is the heating control set on the boiler to the max position??
  3. P

    Serious banging and cool radiators.

    feel the pipes to the radiadtors that are not heating correctly... if one pipe is hot (that is the flow..inlet) and the other is cold... (return..outlet) then I would suspect that they are bloked with sludge..drain down and refill several times use a flushing inhibitor on the last flush.
  4. P

    Serious banging and cool radiators.

    Is it only one radiator the fails to get heat to it?
  5. P

    Part P building regs

    So part P is upon us so how are we doing, how many new showers have we fitted? who has contacted us to inform us of what should be done??? We (plumbers) now must tell building control that we are fitting an electric shower so why is it that electricians that fit the same shower do not need...
  6. P

    Serious banging and cool radiators.

    What boiler do you have?...Have you bled the system? Go to search on this forum and type bleed..bled.
  7. P

    "Get off my land"

    So the queen owns the land, then she swears in the government who we voted in who in turn imposes council taxes upon us to pay for the upkeep of the queen and government so we can live in the house we built or bought on the land the queen owns. GET RID OF THEM......(not the houses)
  8. P

    Sandringham suites...plumbers installers read this.

    Plumb Centre (wolseley centres to the trade) are selling sandringham 4 piece suites BUT...the close coupled pan and cistern appear to have been mis-matched, the pan is "lipped" so the 10mm rubber washer does not make a true seal to the cistern. If you install these buy the thick doughnut washer...
  9. P

    Plumbing in Mira Sprint Shower

    They do don't they!
  10. P

    Durgo

    Air admitance valve works to let air into soil system without letting fumes out. Works on pressure differences. Kev is right 550 -600mm above highest outlet is correct , (seen them under a bath before though??)
  11. P

    What type of shower?

    So my question is: Can I just take a spur off the cold water tank which serves the hot water system and use this as the cold supply for a power shower.. answer is No. A power shower needs to draw its supply, both hot and cold, from tanks so that it is not subject to problems with mains...
  12. P

    Plumbing in Mira Sprint Shower

    Use a 15mm compession elbow, ....push fits will work but like the rest say ****????
  13. P

    No Flow Cold Water Bath

    Is the mixer tap a shower mixer?
  14. P

    Triton Aire Bar Mixer Showers

    I have fitted about six of these..all concealed pipe work..But find the offset connector supplied doe's not leave a lot of clearance for tiling from the back plate to the shroud...anyone use them?? Any suggestions?? I have used tap wing backs..tried 22mm male irons but still not a lot of...
  15. P

    Online bathroom planners

    Doe's anyone know of a good planning/design site for bathrooms..or doe's anyone have a program for the the P.C.
  16. P

    Keeping legs crossed...

    You can get adapters from toilet to cast also flexible pan connectors are available.
  17. P

    hot water in bathroom but not in kitchen help!

    What system is it combi or gravity fed if gravity fed is the hot water cylinder on the ground floor or upstairs?
  18. P

    brown sludge coming from hot taps

    Have you a Combi boiler or gravity fed system? If it is the latter then you may have pin holes in the internal coil in the hot water cylinder?
  19. P

    What is the smallest combi boiler?

    Ideal does a small one, Plumbcentre had it on offer with a heat pack about a month ago in their mag the Grapevine. Should be able to purchase it seperatley.
  20. P

    Short bath wanted. 1640 0r 1650

    1600 is too short 1640 is exact or 1650 with a bit of plaster out!