    Morco FEB 24E Boiler- Adding Wireless Programmable Room Stat

    I've read that the switch should be 0v if I introduced L to it think it would pop the PCB. I had to scratch my head about the power side of things and understand what you mean about the other connectors and connecting to the J4. Your help is appreciated! I'm heading to bed now but will...
  2. P

    Morco FEB 24E Boiler- Adding Wireless Programmable Room Stat

    Thanks a lot for that information and suggestion. I've had a play with a wiring diagram and think its correct. Could you cast your eye over it to make sure i've got it correct. [/img]
  3. P

    Morco FEB 24E Boiler- Adding Wireless Programmable Room Stat

    Hi My parents recently moved into a static caravan that they are living in for 11 months of the year. They have a Morco FEB-24E boiler which they use for their heating and hot water. The boiler works brilliantly except it is very limited in its controls. It has a mechanical clock timer with...
  4. P

    Vokera Compact 24 shuts down when hot

    Mine is doing this now, does anyone have any ideas what it could be. Matt if you got it sorted could you reply on this with what it was. Ta
  5. P

    Vokera Compact Se 28 - Occasionally locking out after 10 min

    The orange.amber light I referred to was because I had not connected up the DHW thermisttor as I was trying to see where the pins were to help get a multimeter in. I tried disconnecting the CH thermistor when off or on and it produces the same kind of results that it is doing when locking...
  6. P

    Vokera Compact 28, Red Light on, locking out & not firin

    Just to finsish off this post, it was the ignition board, as soon as it was replaced it fired up like a good un!
  7. P

    Vokera Compact Se 28 - Occasionally locking out after 10 min

    Hi We have a troublesome Vokera Compact Se 28. It recently about 1 month ago have a new ignition board that connects to the PCB. Up until today it worked fine. I put the heating on this morning and it fired up from cold and heated the radiators for about 10 minutes before then locking out...
  8. P

    Vokera Compact 28, Red Light on, locking out & not firin

    Well tried that and still nothing, it still wont light. I have spoken to an engineer who is coming out tommorrow adn he also thinks it could either the PCB, ignition board (which goes onto the PCB) or the gas valve.
  9. P

    vokera lina 28 hot then cold

    I had a Vokera which did this and I found it to be the DHW thermistor. It wasn't sending a true reading to the PCB and the water would constantly heat up and up until the safety thermistor cut in and killed the heating. The water would cool again and then the boiler would fire up etc and do this...
  10. P

    Vokera Compact 28, Red Light on, locking out & not firin

    What I meant by that was if it's something like a thermistor that needs replacing and we are going to be charged a fortune for a call out and then the part etc then I would change it myself. I'm sure you've seen the BBC house of horrors where you get cowboys in charging a fortune for hours and...
  11. P

    Vokera Compact 28, Red Light on, locking out & not firin

    I've been told it may be one of two things. A PCB or a Gas valve that's gone. Obviously I wont be touching the gas side of things but is there a way of testing to try and rule one or both of these out. Thanks
  12. P

    Vokera Compact 28, Red Light on, locking out & not firin

    The red light came on, on our Vokera boiler yesterday. When i try to reset it as it says in the manual, nothing is happening. Just before it ignites it locks out again & won't fire up. We have no hot water or central heating at the moment. Does anyone have any ideas as to what the problem...
  13. P

    What wattage dimmer do i need - GU10 50w lights

    Ok thanks. If its max of 50% then i'll go for a 600 watt one to be safe.
  14. P

    What wattage dimmer do i need - GU10 50w lights

    Hi, Really simple question for someone out there. I have just wired up 8 x 50watt GU10 Downlighters in my front room. I currently have two switches (One by one door the other by the 2nd door). Each switch either turns them all on or off. I think I need a two way dimmer (only replacing one...
  15. P

    12v and 240v bathroom lights/switches - Is is possible?

    Thats what we've had to do, currently got 35 watts in i think.
  16. P

    12v and 240v bathroom lights/switches - Is is possible?

    The pic above is exactly what i want! You need to produce it! Thanks for the ideas.
  17. P

    12v and 240v bathroom lights/switches - Is is possible?

    The 240v wall lights were already in the bathroom. There's two of them and a 240v ceiling light. The house is only 18 months old. It's like blackpool when there all on hence the low voltage. My wife wants to be able to bath with the lights on without getting sun burn.