    Xeon 60FF not firing

    Hello All, I have a problem with my Saunier Duval 60FF not firing up. If the boiler is complete then it just sparks away and doesn't seem to light the pilot but might fire up after a few mins and might not fire up at all. If the front cover is removed then it lights the pilot better but the...
  2. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    PCB - Printed Circuit Board. In this case it's the electronic circuit board in the bottom of the boiler, which controls everything it does. It's easy to swap really - Switch the power off, remove all the wires (make note of where they came from) squeeze the plastic pillar/clips and the board...
  3. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Gentlemen, thanks for all your help and for maintaining my sanity. Got the PCB swapped, they didn't seem happy, and with the second replacement pcb the boiler fired up straight away. Thanks again.
  4. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Hmm, I see what you mean, I'm thinking more & more it's still the PCB too. It looks pretty genuine from the box. It has "Glow-worm, awb, pro-therm, Bongioanni Genuine factory replacement parts" all over it. I suppose there could be something else wrong which has Kn%$£ked up the replacement board...
  5. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Just re-read your post, do you mean if the boiler "thinks" the pilot is lit before it starts, it won't fire up?
  6. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    The pilot light is not lit. It normally only lights when leds 3 & 4 on the pcb are on. The boiler isn't getting anywhere near to trying to light the pilot light it's just turning the flue fan on & off. I tried reversing the wiring to the fan and it still did the same either way round. I haven't...
  7. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Gasgeezer. Sorry I don't understand. The boiler won't fire up in the first place. All that happens is the flue fan keeps going on & off for about 1 second each time. The pilot should light when the 3 rd led lights but only 1 & 2 are lighting, which according to the manual mean there's a problem...
  8. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    PCB from a pukka central heating parts place.
  9. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Do you mean the pilot light itself? There isn't a permanent pilot. Normally the fan starts & then you hear the starter clicking & the pilot lights, then the main jet comes on.
  10. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    I think you're on the right track. With a flying lead on the fan the 3rd & 4th leds came on & boiler fired up!
  11. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Thanks for the advise, looks like I might have to bite the bullet & "get a man in". Going for some hot soup now, finding it hard to type. If anyone else has any idea's, I'd be grateful.
  12. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    When NO disconnected fan still cycles on/off. APS looks okay with diag Red to C, Yellow-NC, Black to NO. I also took note when I removed old one.
  13. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Front cover is off. The 240v seems to disappear from terminal C on APS when APS clicks..... Almost like when it switches over to terminal NO something turns off the feed to C.....
  14. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Juat changed fan again (Luckily they sent a spare years ago when original started to hum, Fan lovely & clean & new looking) no change. I can hear the APS clicking & can see the voltmeter needle flicker on NO terminal of APS. It seems as though not enough air coming down red tube to switch it...
  15. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Sorry, pc not near boiler! Just checked old & new APS both switch okay when I blow down H. Checked for 240V on NO terminal, no volts so APS not switching? No blockages on pipes, no leaks, fan blowing like a good 'un. ........
  16. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Just to add the fan goes for 1 second & stops for 1 sec etc.
  17. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    If it worked like this then it would prove fan/aps/pipe fault Sorry I don't understand, it must be the cold! The PCB has 4 neons, only 1 & 2 are lighting. The faulting guide indicates an air flowing fault. If neon 3 was lit it suggestes ignition, pilot or flame problem. I've just checked the...
  18. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Whats flame retrification? It has a pilot which automatically fires up normally.
  19. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Yup, it's my own boiler- worst luck. Pipes checked both have no leaks & red pipe confirmed goes from H on APS to near the output on the fan. If I swap them around on the APS the fan runs continuous but still no led3 or boiler firing up. Huge blast of air out the flue, no change of I block flue...
  20. J

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    The boiler won't fire up, the flue fan just keeps stopping & starting. Followed Faulting guide & swapped Air pressure switch & control board, checked all piping, also swapped fan but no change. Any idea's? Also what is the Air pressure switch actually "looking" for? Positive pressure down the...