Search results

  1. P

    Removing Lincrusta frieze temporarily

    We are looking for advice for removing a lincrusta frieze in a Victorian house safely so it can be put back again once building work is complete. The wall it is on is being removed and a RSJ going in behind where the lincrusta is currently, We have removed the picture rail and thinking a flat...
  2. P

    Air issue with UFH - Solar Filling Pump?

    I've got a relatively new UFH system on an existing S Plan with system boiler & unvented cylinder. The UFH has never worked properly which we think is due to air in the system, the main symptom being the Wilo pump will flash red/green and stop pumping water around the loops. Despite flushing...
  3. P

    Intermediate light switch issue

    Thanks, that was indeed the issue. I couldn’t remember how the live & S/W live were connected to COM, L1 & L2 in the Wago as it’s now inaccessible. Joined the COM (blacks) in the back of the intermediate switch & connected brown to L1 and grey to L2 which sorted it.
  4. P

    Intermediate light switch issue

    Yet another post about 3 way light switch wiring! I've read quite a few posts but I have an odd one which still can't make head nor tail of despite checking & double checking wiring diagrams. I have 2 x 2 way switches at each end with intermediate in the middle. With the current wiring the...
  5. Intermediate switch

    Intermediate switch

  6. 2 way switch (2)

    2 way switch (2)

  7. 2 way switch (1)

    2 way switch (1)

  8. P

    Reverse flow with UFH & rads?

    They were originally according to the design spec. The pic shows far right and far left fully open as I was just testing what would happen with a couple of circuits running rather than all of them (still the rads were heating up)
  9. P

    Reverse flow with UFH & rads?

    Got a bit of an issue with a newly installed UFH system on an existing S Plan with system boiler & unvented cylinder. The UFH has been added to a new first floor of the property which includes rads in the rooms without UFH. A branch has been taken off the 28mm flow and return from the boiler to...
  10. IMG_8562

    IMG_8562

  11. P

    Cutting tapered strips to fill gaps between door & frame

    Huge amount of work to remove, re-plaster the inevitable loose bits around the frame, refit and redecorate. They are the original Victorian deep frames & architrave.
  12. P

    Cutting tapered strips to fill gaps between door & frame

    As part of a project to upgrade some old Victorian doors to 20min fire doors (agreement with building control), I need to decrease the gap between door and frame on several of them and them use Intumescent coating on the internal side & edges of the doors. Then finally fit intumescent strips...
  13. P

    Can't get radiator bleed screw to seal.

    I've got an old cast iron panel radiator that I've recently had stripped and repainted. On piping up it has a weeping leak from the bleed screw at the top. Taking the screw out and cleaning up I could see the screw thread has a notch in it and the hole that it screws into also has notches in...
  14. IMG_7999

    IMG_7999

  15. IMG_7997

    IMG_7997

  16. P

    Omnie TorFloor UFH - anyone used it?

    I did yes, although it is not up and running yet as I've not finished the renovation project. Having never installed one before I found it easy to install once I'd read all the instructions and watched the skill builder youtube videos a few times. The components sent are good quality and the...
  17. P

    Levelling between shower tray and plywood floor

    We've just laid a wet room shower tray former (30mm) thick direct to joists as specified. Unfortunately the floor around it isn't quite level which is a suspended floor again with UFH and overlaid in 6mm plywood (glued & screwed). To bring the floor level with the shower tray (which is...
  18. P

    Alexa relay for existing door bell

    Yes 12v at the bell point along with the door push. Shelly 1 sounds like a good option, the blurb says it can be used to detect a door bell push. I just need to find a wiring diagram to find out how to do it :)
  19. P

    Alexa relay for existing door bell

    I've got a victorian style 12v wired door bell in my house but looking to modify it so it could notify the various Echo Dots I have around the house. A routine would be straightforward enough, but need a relay or similar that would get triggered when the door bell is pressed. Doing a search...