    Sage coffee machine

    We do not have hard water in Glasgow so limescale is not an issue. Though I regularly use the tablet to clean the filter using the supplied rubber disc when cleaning light comes on.
  2. D

    10mm microbore 90-deg bend exiting wall

    No insert normally needed for compression fittings but as said olive can at times fail so I almost always go to 15mm yorkshire adapter
  3. D

    10mm microbore 90-deg bend exiting wall

    The microbore pipe is quite soft. Olive at times will crimp the pipe and pipe deforms so much that the olive no longer forms a seal In fact, where copper pipe is soft, internal sleeve is required to strengthen the pipe wall same as required with plastic plumbing ( 15mm copper pipe coils)...
  4. D

    Did my gas engineer do it correctly?

    Is the boiler a combination type? If I put chemicals in the system, post cleaning I flush them out with multiple flushes, then add inhibitor Appears the boiler may be a Vaillant. Issue needs looked at.
  5. D

    Replacing Baxi 105e PRV - missing part.

    Look at the pipe you removed from the old prv. The capnut should fit the new prv
  6. D

    10mm microbore 90-deg bend exiting wall

    I always do this. Have been to radiators where the pipe has squashed and starts to weep
  7. D

    10mm microbore 90-deg bend exiting wall

    Done that many times. Mini bender is perfect for this
  8. D

    Constant leaks from pipework around hot water cylinder

    I prefer not to use joining compound If a joint leaks, it is because the olive might not be a quality one or fitting issue. In that case PTFE on the olive will sort the problem These are manipulative fittings ie at some point will need dismantling. Jointing paste when it goes hard will cause...
  9. D

    Constant leaks from pipework around hot water cylinder

    Nothing to do with Kingspan, if the couplings are leaking, then it is shoddy workmanship or type of fittings used. Only cylinder related issue is tundish showing discharge due to expansion issues but that would not happen if cylinder saw proper aftercare
  10. D

    Leaking from outside boiler drain after refilling central heating

    Did you use the boiler pressure relief valve to drain the system? If yes, there is your answer
  11. D

    Sour dough bread

    Don’t knock it till you try it is what I have to say.
  12. D

    Sour dough bread

    Post 121. Claims to cure that issue but that could be snake oil
  13. D

    Sour dough bread

    Did you see the picture of sourdough with charcoal added to it?
  14. D

    Double for single connection issues

    Best to renew from the solder elbow Rest is going to be a botch
  15. D

    Triple panel radiator and legs

    Obviously will weigh more. In the past when had to use these, walls were brick so no issue- did not need the brackets.
  16. D

    Private Number Plates

    Gardening chap’s sign written van says “ we will trim your bush”
  17. D

    Private Number Plates

    LU61FER LUCIFER
  18. D

    Some initial observations on the use of smart trvs on all the rads. (Zero zoning)

    Welcome to multi zone controls. Had it a while and fitted several
  19. D

    screwfix tank connector leaking

    Maybe they are woke and see you coming and say to themselves “I am woke, charge this man woke tax”