  1. T

    Very strange symptom - firebird boiler Reillo burner just blowing

    FFS try a new cell with a 530 SE. Talk about Blind leading the blind.
  2. T

    Very strange symptom - firebird boiler Reillo burner just blowing

    If I was on site my first step would be to fit a new box and cell to eliminate them, Then for vitiated air in the snorkel if fitted, (balanced flue)
  3. T

    Trianco TRG 60 (just lost the vent cleaner inside)

    To gain access to the sec air ducts the Fire grate and clinker ejector ram must be removed.
  4. T

    Trianco TRG 60 (just lost the vent cleaner inside)

    https://www.google.co.uk/search?sca_esv=956dd3d9e5d35c29&sca_upv=1&biw=1275&bih=621&sxsrf=ACQVn09TRUgmyRJILKXSFq7mbW26EHx4aQ:1712757601466&q=Trianco+trg+60+manual+pdf+download+free&sa=X&ved=2ahUKEwji8K6j57eFAxVp9QIHHe9GCWcQ1QJ6BAgkEAE
  5. T

    Trianco TRG 60 (just lost the vent cleaner inside)

    Is the boiler lit? IF not the flueways are directly above the fire bed. Keep operating the clinker ejector until hopper is empty The scraper head may have fallen through.
  6. T

    Camray 5 Boiler - Issue

    Which Camray is it? Which control panel was replaced
  7. T

    499k Mx boiler thermostat phials

    Clean the heat conductive grease from the phials and pockets and try again.
  8. T

    Danfoss Type HSA3

    No its a different beast!
  9. T

    Part came off……..Oil boiler

    Oil pressure test point
  10. T

    Drayton ZA5 Actuator fault

    If you have knacked 4 actuators...... The valve must be foooked!!
  11. T

    Powerflush through boiler

    If its a Powerflush the unit has a pump.
  12. T

    Drayton ZA5 Actuator fault

    IF the other valve is close to it.. Swap the heads and see what happens.
  13. T

    Worcester Heatslave 20/25 fan keeps running

    The slave tank should be fully heated PRIOR to running a bath
  14. T

    Worcester Heatslave 20/25 fan keeps running

    If you want to retain a post purge to prevent smells. I have a P P unit removed from a leaking boiler you can have for a sensible price, I have retired so no use to me. The diverter fails to H W supply ie No Heating.
  15. T

    Worcester Heatslave 20/25 fan keeps running

    The easy way to isolate the post purge is to simply put the motor wire into the satronic base motor terminal and connect the wires to PPU together in the now free connector. Live feed to PPU should be made safe.
  16. T

    BSA Hotspur Oil Boiler

    I watched the video again .......... That Kero looks suspiciously like H2O. If the tank is same vintage as boiler and recent weather is taken into consideration!! Check OCV filter and whilst removed run a few pints into clear bottles. Or dip tank with water paste.
  17. T

    Back boiler won't fire up - faulty controller?

    I would guess a trapped melted wire,
  18. T

    BSA Hotspur Oil Boiler

    The spark should strike the flame ring not the grille. It was normal for a hole to be eroded at this point,. Repair clips were used. the spark should be crisp and blue like an arc weld
  19. T

    Sink drain pulling vaccum on boiler condensate trap

    Should be an air break to prevent it.