  1. petit_pablo

    BBC can’t be real can it!

    Probably is...Russia have been arresting lots of anti war protestors. She'd be old enough to remember the old soviet union under Stalin too.
  2. petit_pablo

    Gas Boiler Flue

    Its technically ok just doesnt look too clever.
  3. petit_pablo

    Unvented vs vented HW cylinder?

    Without knowing what your mains pressure and flow rates are we can only give a subjective answer. The tap may only be providing 10lpm due to narrow flexis, flow regulators or filters within it. If im quoting for an unvented i always check dynamic pressure and flow rates at an unrestricted...
  4. petit_pablo

    Leaking toilet

    +1 More likely its dripping down onto the pan connector from the flush pipe above.
  5. petit_pablo

    One leak triggers another

    Its really not difficult to take out or refit on a logic and it shoudnt be brittle unless its been subject to some serious heat.
  6. petit_pablo

    One leak triggers another

    How the hell did they do that?! Was it cleaned with a hammer? OP it will be a condensate leak if its doing it mostly on CH.
  7. petit_pablo

    Worcester Bosch Greenstar 8000 Life problems....Or are they???

    Funnily enough ive had a call this week from a customer i fitted an 8000 for. Same problem...WB are going out to it under warranty
  8. petit_pablo

    Strange smell in workroom.

    Because whatever it is, is being heated by the radiator causing the smell.
  9. petit_pablo

    Moving Rad - floor joist in the way

    We're making a meal of this. Notch the joist and use a 90 elbow. Pulled bend wont give you the tight radius you need.
  10. petit_pablo

    Hive Combi installation

    The hive receiver would clip onto that existing backplate.
  11. petit_pablo

    Weeping compression fittings

    Never used to use anything on compression joints but with the poor quality of fittings these days and the fact i started getting a lot of fittings weeping has meant i now use jet blue on the olives. Since then, all good again.
  12. petit_pablo

    Adapter to reduce big bath tap?

    Quick question....why? (n)
  13. petit_pablo

    Warm Air Heating Usage & Removal - Extremely Worried about Abestos Exposure

    Id take the surveyors observations with a pinch of salt re the ductwork as i dont imagine they know one end of a warm air unit from the other. Chances are the flue pipe will be single wall asbestos cement not the ducting with will be sheet metal
  14. petit_pablo

    Any one use or heard of jet swets?

    Only really useful if your cutting in a new isolation valve or replacing an old one.
  15. petit_pablo

    Gas Hob

    This....because from what you've said OP, the guy hasnt a clue.
  16. petit_pablo

    Have I killed my 'boiler'? Help please.

    Entirely possible the boards popped...if you put the N from the old stat onto NO on the new one you've railed 230vac down the neutral
  17. petit_pablo

    Whats worth taking to the scrap yard?

    Copper is worth taking if you've got a decent amount. The rest isnt worth the fuel to get there.
  18. petit_pablo

    Is fernox f3 safe left in for a month

    Be fine....F3 can be left in indefinately, its not very strong.
  19. petit_pablo

    Flush?

    I'll add on..if it smells chemically, it looks like cleaner has been left in. Fernox F5 looks that colour after a while