  1. m33ksy

    Washing machine starts to spin then stops

    Hi, I have a Beko Wm6123w washing machine that was making loud banging noises and would try to spin then stop. Now it doesn't bang but it starts spinning and as it speeds up it then stops again and it keeps doing this. So far I have opened it up and looked at the belt it seems ok and the springs...
  2. m33ksy

    Potterton Powermax HE 'A15' Lockout

    Hi all, firstly apologies for such a long post! However any help would be greatly appreciated. I have a potterton powermax HE boiler. It has recently had a new diverter valve and a new pcb and been serviced and all was well for a few weeks until now, Last week I noticed the pressure was low...
  3. Untitled

    Untitled

  4. DIY

    DIY

    Random DIY pics
  5. m33ksy

    Radiator Cold Goes Hot When Bled Then Cold Again

    Hi it's now working fine. Took the radiator off to flush it and some blackish water came out but not really any sediment but realised water was only coming out one end. Turns out the side the trv is on the radiator had a plastic cap screwed in it no wonder no water was flowing! I guess the...
  6. m33ksy

    Radiator Cold Goes Hot When Bled Then Cold Again

    OK that kind of makes sense. So your saying even if I take the radiator off and try each valve they could both show good flow however the trv could still be knackered?
  7. m33ksy

    Radiator Cold Goes Hot When Bled Then Cold Again

    Many thanks i'll try it tomorrow and let you know how I get on. Thanks everyone for your help so far :)
  8. m33ksy

    Radiator Cold Goes Hot When Bled Then Cold Again

    I think that is going to be my next option. Removing and draining. Also will make sure the radiator is not blocked. Should the flow be the same out of both sides?
  9. m33ksy

    Radiator Cold Goes Hot When Bled Then Cold Again

    Hi sorry, It's a sealed system i've been making sure pressure is good currently at 1.7 cold.
  10. m33ksy

    Radiator Cold Goes Hot When Bled Then Cold Again

    Hi rojaca thanks for that. update. Yesterday both pipes were cold as I said until I bled out some water and then the lockshield pipe gets hot and radiator goes warm after quiet a while then lockshield and radiator go cold again. Today however when the heatings come on the lockshield pipe is...
  11. m33ksy

    Radiator Cold Goes Hot When Bled Then Cold Again

    I tried bleeding with one valve closed at a time and doesn't appear to be a blockage. Both pipes still cold though when heating is back on. I guess it must be the TRV even though I took the top off and the pin seemed fine wasn't stuck or anything. Maybe I should try what past3bar said pulling...
  12. m33ksy

    Radiator Cold Goes Hot When Bled Then Cold Again

    I have closed the lockshield and am bleeding again, It sounds the same as before, there is is flow and doesn't seem to be stopping, Should i keep bleeding till the flow stops then try reopening the lockshield? Thanks
  13. m33ksy

    Radiator Cold Goes Hot When Bled Then Cold Again

    Hi sorry if this has been covered somewhere but I couldn't find it. I have 1 radiator that is cold and both pipes are cold too. If I bleed for a while (Sounds like water and air coming out) one pipe gets hot and the radiator starts heating up but the pipe with the trv doesn't get hot. Then...
  14. m33ksy

    The not so proud owner of a troublesome potterton powermax boiler!

    The not so proud owner of a troublesome potterton powermax boiler!