  1. G

    off grid 240v system 24v batteries 4 230watt panels

    thanks for the reply no i have double checked all the polarities on all the connections it all works fine without the meter connected, any way i have tried the connection to the small plug on the board the other way but it still trips, i do not consider myself incompetent after years...
  2. G

    off grid 240v system 24v batteries 4 230watt panels

    Hi i am in the process of building an off grid stand alone 240 v ac system for my shed and garden use basically i am using a 24 volt dc input pure sine wave 1500watt peak 980watt cont the output goes into a garage type 2way rcd unit with 6amp and 16 amp trips, the rcd...
  3. G

    question about S O R N on a car

    well i have been told by a policeman that if a car does not have insurance even on private property then it has to be sorned. Nobody seems to be reading my post properley all i was saying was that the lady sorned the car that my son bought even though the tax did not run out until...
  4. G

    question about S O R N on a car

    hi both just to clarify, the lady my son bought the car from cancelled the insurance, and was told that she had to sorn it to stop he being prosecuted for no insurance, but she did not surrender the tax disc, that stayed on the car, so now she has sold it the sorn is no longer...
  5. G

    question about S O R N on a car

    My son has recently bought a car with mot and tax until Nov 2011.The lady he bought it from had to transfer her insurance to a new vehicle but now under the new laws all cars have to be insured even if they are on your property.She was told to S O R N it to make it legal...
  6. G

    Distance between houses

    Hi i just put in plans for a proposed extention but as it was under a certain size it only needs a building notice and a sketch of the ext and a drain details, however the planning office did point out that the 1996 Party Wall act could apply and i think it will apply...
  7. G

    Ravenheat 3 way diverter valve replacement costs

    I have looked at this problem for years so i got in touch with giannani and they told me that they make them to suit ravenheat boilers, and the pressure of the springs are different to the lookalike valves, even though they look the same, i used one once. and the boiler would not cfire up...
  8. G

    Ravenheat RSF820/20 problem

    Hi have you checked that the pilot has not gone out these 820s still have a pilot and the fan runs at low speed to keep the combustion chamber air coming in, its worth checking before you try anything else If thats ok turn it off at the wall for 5 mins and then back on again...
  9. G

    10 old school cast rads all sizes

    Hi just repaired a boiler today in a hoarders house and i mean horder. It is a pallisaded 3 storey type dwelling and in the entrance hall is a pianola with rolls for self playing. Every room is filled with items of funiture etc In the kitchen amonst the piles of old tables and boxes are...
  10. G

    17 year old employee my grandaughter advice req

    Hi everyone and many thanks for all the input and advice all i want for her is to have her money paid back to her so that she can move on, on advice from A C A S, my granddaghter has now written to the manager asking why have they deducted £86 plus from her wages without her consent...
  11. G

    17 year old employee my grandaughter advice req

    Hi all i am placing this to see what others think about the way my granddaughter has been treated at he first job after leaving school, She was taken on by a fitness center hairdressers inside the complex at the interview she was told that they would have alter her hairstyle cut and...
  12. G

    trojan horse infection

    Hi can anyone please tell me how do i get rid of the trojan horse infection i have A V G installed and it is telling me i am protected but i keep getting an alert from A V G telling me i have a threat on 2 files but after pressing the remove button it came back telling me some files...
  13. G

    need to change large rad for 2 smaller ones on 10mm microbor

    we used to do loads of these type with 2 small rads so you need to connect 1/2 m/iron to 15 mm copper addaptors to the top and bottom of each rad times 4 at the middle so connecting them together with 15 mm copper then feed your micro bore flow/return to the bottom of...
  14. G

    Ravenheat 820 20

    Hi normally the fault would be down to the diverter valve because the power from the boiler pushes down the heating pipes the diverter valve should close off the port to the heating when calling for water only If you have low water pressure coming out it could be the mesh...
  15. G

    self employed N I C no benefit to payee at retirement

    Thanks for all the replies Big All /// Self employment did have a lot of rewards i suppose over the years and in 1975 i deciced to take out a pension for my retirement that was £22 per month index linked over the years with the projections at the time and with increase in...
  16. G

    self employed N I C no benefit to payee at retirement

    Hi after being in business since 1972 and paying all the demands in tax etc I reached retirement age and decided to claim my pension and work part time as an when i wanted to. That was 3 years ago. My brother was due for retirement and had his forecast and I was amazed how much more...
  17. G

    jaguar 1995 xj6(x300) power steering fluid loss

    Hi my brother has a jaguar x300 1995 and has a problem with steering fluid loss he so far has filled up the small header tank 3 times and its all gone in a matter of 2 weeks i have had a look and there does not seem any sign of any leek showing externally, i do know that the 2 pipes...
  18. G

    Mira 88 - Fit service kit

    Hi there were 2 models of the 88 the old one has a large union nut on each side if its that model then its best to undo those then you can twist it round to remove from the centre fixing there are fibre washers on each one The other model has square type unions and are...
  19. G

    Ravenheat RSF 820/20 Boiler

    hi dont forget the water temp going in this weather must only be about 5 deg and the boiler is rated to heat the water up with a flow rate of 9 lts at a 35 deg rise above the incoming temp so you need to measure the cold in and the hot out and the flow rate and work out what...
  20. G

    Ravenheat rsf 820/20 possible prv problem

    Hi if the pressure rises then the fill up loop must be passing through meaning the tap is not turning off fully By the way the fill up loop should not be left connected owing to cross contamination could happen as it is connected to the heating pipe and could get the heating...