Search results

  1. C

    Viessmann Vitodens 200 S plan wiring configuration

    Just checked the wiring configuration of the 200w that you have, and there is a difference, your right on your boiler its plug 96 with 230V. I'll try and scan my wiring diagram in and post it if I can.
  2. C

    Viessmann Vitodens 200 S plan wiring configuration

    Sorry Picasso Its the Viessmann Vitodens 200 WB2, not the most recent 200. Its about 4 year old. The wiring diagram I have is from the Service Instructions for heating engineers. Serial no: 7170311302850106 Just wondering if I could put a no volts relay between X4.1 and X4.2 switched by the...
  3. C

    Viessmann Vitodens 200 S plan wiring configuration

    Plug 156 is the system supply for accessories 230V. The wiring diagram shows that the external connections X4.1 and X4.2 (jumper lead currently fitted) for external demand are 24V. The supply to the wiring centre, programmer and 2 port valves is 230V from plug 156. So the Switched live from...
  4. C

    Viessmann Vitodens 200 S plan wiring configuration

    Central Heating system split into 4 zones 3CH and 1DHW Honeywell 2 port valves controlled by Honeywell ST6400 controller and room thermostats. Just had Viessmann boiler as replacement and the switched live into the boiler from the wiring centre needs to be 24v incoming. The existing switched...
  5. C

    Viessmann Vitodens 200 Programme Unit

    Just bought a 3 year old refurbished Vitodens but the removable programmer got broken during transit. Looking at the spare parts list, there are 3 different programming units, a weather compensated unit, a constant temp unit and a Comfortrol unit. My current set up is an S plan using Honeywell...
  6. C

    Condensing Boiler Heat Exchanger Calcium (build up)

    I think I get the message, KESTONS are RUBBISH, but unfortunately in the current economic climate a replacement is not an option, I'll have to nurse this one for a couple of years. Saying that the ridiculous cost of their spares (£7 for a burner gasket) will make any major repair prohibitive.
  7. C

    Condensing Boiler Heat Exchanger Calcium (build up)

    Just read up on what a hydroflow is but can't see how that would help as the buildup is due to the water in the combustion gases. Anyway spent the afternoon gently descaling the large lumps, there must be some type of solution that can be used to break down the remaining deposits. Any...
  8. C

    Condensing Boiler Heat Exchanger Calcium (build up)

    Having removed burner and electrode from Keston 170, was amazed by the amount of calcium build up inside the heat excanger, the top coil was completely encrusted with the stuff and a large build up in the base of the centre chamber. Is this normal or indicative of condensate drain problems or...
  9. C

    Boiler Ignition cable Testing

    Always wondered what break dancing was all about.
  10. C

    Boiler Ignition cable Testing

    Thanks Nicknox Who'd have thought the flame could complete the circuit. Any ideas on the ignition cable.
  11. C

    Boiler Ignition cable Testing

    What would be a good (average) resistance reading to obtain when checking a HT ignition cable. Could some one explain how this cable provides flame sensor feedback to the control box to extinguish the spark. I would mention the make of boiler but ChrisR might just order me a skip.
  12. C

    Fluorescent Light with 4 Terminals

    The ballast is a Vossloh Schwabe no 922428, just to add to the confusion I have 2 of these lights and just taken the cover off the other, this also has a 4 terminal block but is labeled L/v, L/f, E, and N but this time the L/v goes to the ballast.
  13. C

    Fluorescent Light with 4 Terminals

    Its a 702mm Cryselco Proteus single PDX1218
  14. C

    Fluorescent Light with 4 Terminals

    Thanks for that quick response I'll take the cover off in the morn and post a pic.
  15. C

    Fluorescent Light with 4 Terminals

    I have a Flu light to fit and the incoming mains terminal has a 4 terminal block connector with L, N, E and a N/v terminal the Nv wire is blue and white and goes to the ballast. should the mains neutral be connected to the N or N/v
  16. C

    Stuart Turner Single Impeller Shower Pump

    Sorry I should have explained better. I have a negative single impeller pump feeding a Hot water tap in the loft extension. My thermostatic mixer pressure is only about 0.80m. I thought perhaps a 22mm Tee off after the pump might boost my supply pressure. Could I possibly tap off the cold mains...
  17. C

    Stuart Turner Single Impeller Shower Pump

    Can a single impeller pump be used to boost just the Hot water to a thermostatic shower mixer valve with the cold fed from cold water storage in the Loft. Wont there be a pressure difference at the valve ?
  18. C

    Zilmet 25litre Expansion vessel and Robokit

    I am asking because as I stated in my first post that Zilmet, Watts and Altecnic all conflict in their website advice and as your post points out there is a difference in opinion,Thank you very much I will heed your f**** advice.
  19. C

    Zilmet 25litre Expansion vessel and Robokit

    Watts who supplied it recommended system connection on top.
  20. C

    Zilmet 25litre Expansion vessel and Robokit

    Could someone please enlighten me. Does it make a difference to which way the vessel is orientated ie Robokit at the top and air charge point on the bottom or Robokit and system connection at the bottom with air charge on the top. Looked up different suppliers instructions on the web but they...