  1. past3bar

    alpha HE 33 boiler tripping RCD when windy

    No definitive answer ? I was called out to a 33HE tonight with the exact same problem.
  2. past3bar

    bathstore metro shower mixer triple

    I am looking for an alternate supplier of replacement cartridge for the shower mixer valve. It is approx 8 years old & dripping. Bathstore want £156.00 for a replacement! Any ideas?
  3. past3bar

    Hi I have painted my bathroom with special bathroom paint and painted onto plaster but round the...

    Hi I have painted my bathroom with special bathroom paint and painted onto plaster but round the window the emulsion as just flaked off. Can anyone enlighten to why this as happen!
  4. past3bar

    lashers on the lash

    lashers on the lash
  5. past3bar

    Alpha cb24

    May well just require new DHW thermistor but probably requires a new diaphragm in the diverter valve. Buy the genuine one as although expensive comes with all the fibre washers & seals. Can be a right pain with leaks so replace all the washers you remove!
  6. past3bar

    converting one house into two

    Thanks for that Freddy I'll contact my local Building control next week.
  7. past3bar

    converting one house into two

    I am in the process of purchasing a large end terraced house which has main road frontage to the gable end with door & windows on ground and upper floor. The side of the house is on a side street at right angles to the main road with a bricked up door but windows on this elevation. The other...
  8. past3bar

    Central heating off but radiators still hot.Why???

    Probably by-passing at diverter valve. Do you have any more information on model of boiler?
  9. past3bar

    Combi boiler and HW tank

    You probably need to decide between an unvented cylinder and heat only/system boiler or a combi boiler. Either way you can lose the tanks.
  10. past3bar

    Worcester Bosch conbi Fault

    Are you sure it's E4 and not EA or FA?
  11. past3bar

    Worcester 24i RSF issue

    Does your boiler have an external roomstat? If so check it is calling for heat/ I would be inclined to bridge out the timer Ci-Cl the clocks do go a bit dicky sometimes. See if it stays on .
  12. past3bar

    Worcester 24i problem

    Is it a standard 24i RSF? Has the overheat stat tripped? Small red button sort of + shaped on top of case left hand side
  13. past3bar

    Dual controls but downstairs cold

    You have 2 x 2port valves somewhere? Sounds like one may be stuck. Hope you have a by-pass on this system.
  14. past3bar

    Halstead Ace problems

    CH Thermistor
  15. past3bar

    bath hot water tap HELP

    Is tap fully open? Have you tried backing the tap up? Reduce the flow- see if temp improves
  16. past3bar

    noisy boiler sounds like it will explode

    If it sounds like a plane landing it usually means the heat exchanger has debris in it or is partially blocked This may be a piece of fibre washer dislodged when you changed the dv. Probably needs taking off and cleaning but you need RGI to do this. If you're lucky it may just be some air...
  17. past3bar

    noisy boiler sounds like it will explode

    If the boiler is functioning correctly in Hw and CH you can probably rule out the diverter unless you have left a bit of fibre washer in the system and its stuck in the heat exchanger. Does it sound like a plane landing? Could alternatively be a host of other things like a noisy or failing...
  18. past3bar

    Eco tect boiler too hih water level (bar)

    Most boilers have a drain valve fitted. You may also have one on your heating system. If not try opening the vent/bleed valve on a radiator and let some water out into a bucket.
  19. past3bar

    Hot/Cool/Cold rad

    Some of these types of rads can only flow one way. Can you check the installation instructions or contact the manufacturer?
  20. past3bar

    Microbore heating problems...

    Has anyone tried adding a chemical cleanser to the system to see if circulation is improved? Is your system properly balanced, are the valves properly open? If you do powerflush or mains flush and some radiator valves leak they can be tightened up or are relatively inexpensive to replace...