  1. H

    Self-cutting tap is leaking

    they certainly do gasservice1985, DIYnot to me means helping people NOT make mistakes in DIY, if it was to deter people from doing DIY, it should be called diyNOT!! lol
  2. H

    Self-cutting tap is leaking

    in my experience, when you use an old drain off, it usually leaks afterwards anyway. we always shut a radiator off, take it off & drain it from the valve, OR as kev says, if theres a void under the floor, just cut into it below the boards & let the water drain into the abyss below lol
  3. H

    alpha HE 33 boiler tripping RCD when windy

    hi Agile, thanks for the reply, but the RGI has been and inspected the boiler internally, and said there is no problem (point 9). he says there is no internal problem. but i know 100% that the supply up to the boiler is working fine, tested with fluke 1652 calibrated 3 months ago. there must be...
  4. H

    alpha HE 33 boiler tripping RCD when windy

    hi, picked a job up today from a landlord saying gas fitter been out and blamed faulty electrics for RCD tripping so went out to investigate. Apparently this has been going on for 4 years since it was installed. story so far. 1. boiler fitted 2008, trips RCD in cellar out roughly once a week...
  5. H

    vaillant turbomax plus 824e - hot water fault

    hi thx for the reply agile, the fan did need replacing as it was very noisy. he didnt test that as far as i know, and he did admit he had never worked on a vaillant boiler before. we were going to call him out again after the new year, but i will run this test when i get back home after the new...
  6. H

    Placement of hot water cylinder and cold water tanks

    if you had both tank and cylinder in the loft or tank in loft & cylinder downstairs your pressure at the tap will be the same.your head pressure (hight of water level above outlet) will still be exactly the same.fill a 2m length oh hose pipe with water, if both open ends are the same level no...
  7. H

    vaillant turbomax plus 824e - hot water fault

    hi, I'm having a problem with my vaillant boiler. the problem started a couple of weeks ago, where i had problems getting it to run at all. We had it serviced & the fan replaced. A few days later we had the problem that the heating would not turn off & had a new programmer fitted (old one was...
  8. H

    SDS core drills

    touche
  9. H

    Fixing a heavy basin to a brick wall

    the bolts will be at the top of the basin, so the actual stress is at the bottom of the basin against the wall, its called a cantalever, the wall under the bolts takes the weight, the bolts just form a pivot.
  10. H

    Gainsborough Shower. Water from outlet pipe

    theres a little grey ball should be in the pipe, common fault, even if the ball hasnt gone down the plug hole & u put it back it will soon blow out again, my advice is swap for a triton. btw is it the teardrop shape? (wider @ top) had a lot of that problem with those when they did the silver ones.
  11. H

    hot water cylinder stuck gate valve

    thats great, but you're nacked if the old 1 is fine threads :P
  12. H

    hot water cylinder stuck gate valve

    if u need to drain the cyclinder (drain offs never work) remove the top connection off the cylinder(wrap a sheet round to mop what spills) then drop a hose pipe in with a foot of copper stuck in it & syphon it out. (the copper stops the pipe curling in the cylinder)
  13. H

    central heating wiring probs still, Please help

    got this sorted today thx had to get my dad round & help me with a wander lead to identify all wires in & out instead of just what they went to. its not paid work, its my sisters house who has no money, no insurance & 2 kids to keep warm & a nob of a husband that left her with sod all...
  14. H

    central heating wiring probs still, Please help

    to kevnurse very helpful, youre an A1 TOOL, congratulations. Id rather start from scratch than a nob like u help me. i will rewire it myself tomorrow if nobody can identify the wires, its not in my house. just thought it easier than ripping the laminate up & rewiring with a new system...
  15. H

    central heating wiring probs still, Please help

    programmer first 2 are n & l, e is a block at bottom but programmer is double insulated
  16. H

    central heating wiring probs still, Please help

    http://www.salus-tech.com/resource-centre.html top 1 click manual :S
  17. H

    central heating wiring probs still, Please help

    http://www.salus-tech.com/TC100MANUAL4WEB.pdf this seems more in relation to the system im working on. if i cant find a solution tonight im going to have to re-wire it tomorrow :(
  18. H

    central heating wiring probs still, Please help

    new programmer is the ep200 http://www.salus-tech.com/manuals/EP200%20&%20EP100%2020%20PAGE(8).pdf
  19. H

    central heating wiring probs still, Please help

    programmer is just a cheapo one, only wiring diagram with it is: N-L-DH off-CH off-DH on-CH on old programmer was melted in fire, not recognisable. sparky came, ripped it out & cut wires, then didnt come back. its ex council house so maybe that helps, heating been in 25 years+ i would...
  20. H

    central heating wiring probs still, Please help

    is this info not helpul at all? im sure securespark can help, you usually straight in there :P