Search results

  1. P

    BAXI 105HE No hot water

    The diaphragm has to move (pin activates microswitch) for the diverter valve to open for hot water.
  2. P

    BAXI 105HE No hot water

    Yes that's it.
  3. P

    Glowworm energy r18 wont switch off , no control

    It sounds like you have a stuck motorised valve , do you have 2 x 2 port or a 3 port valve? (normally found near the hot water cylinder)
  4. P

    BAXI 105HE No hot water

    Its probably the venturi that's disintegrated.
  5. P

    S-plan+unvented cylinder with combi ?

    Yes its doable, the 2 zone valves control the central heating water to heat the rads and/or the cylinder coil.
  6. P

    Ventilation for gas hob

    If you have an extract fan ducted to outside you dont need any further vents.
  7. P

    Deciphering UFH pump & manifold

    Stick the pump on a 3 pin plug and see if it runs, if it does then the sensor if faulty.
  8. P

    vaillant thermostat wiring

    Yes you will need a vaillant control centre (vr66 vr71 ect)
  9. P

    Vaillant Ecotec 30 Pro heat problems

    The boiler would not run if the pump wasn't running, have you opened the valves fully on the flow and return ?
  10. P

    Boiler pressure keeps dropping. No leaking

    Boiler make and model ?
  11. P

    Vaillant 418 going a bit wild

    After 10 years a stuck microswitch in one of the 2 ports would be more likely the problem.
  12. P

    Performa 28i not starting after radiator removal - advise please

    Is the fan running when its trying to start ?
  13. P

    Combi hot/cold crossover in shower mixer

    Might be a good idea unless you fancy doing it in scuba gear.
  14. P

    Combi hot/cold crossover in shower mixer

    Its part of the mixer, if you undo the large nuts holding the shower to the wall the nrvs are in the "legs".
  15. P

    Combi hot/cold crossover in shower mixer

    The nrvs are in the wall mount supply to the shower , you would need to take the shower off the wall and clean or replace .
  16. P

    Promax FSB HE - central heating not working but hot water still fine.

    Ok start with the ch zone valve, with the controls calling for central heating see if the lever on the ch zone valve is easy to move or has a fair bit of resistance.
  17. P

    Promax FSB HE - central heating not working but hot water still fine.

    It could still be connected, try turning it down and up a couple of times and see if it clicks.
  18. P

    Promax FSB HE - central heating not working but hot water still fine.

    As the boiler fires for hot water it’s not a boiler fault, check the thermostat first and post a pic of the heating valves( near your hot water cylinder normally)
  19. P

    Natural gas detector?

    All new hobs have a built in safety device to stop this happening, so new hob is the way to go.
  20. P

    Does a small sink for a kitchen island need an overflow?

    Your taking a chance of ruining your floor covering if no overflow, if your on ground floor and the risk is acceptable go with the sink you have.