Table of Contents

2 way intermediate also known as 3 way

Schematic
:electrics:lighting:schemint.jpg

Switch terminals

:electrics:lighting:switches8sm.jpg:electrics:lighting:l123.jpg
Hint, if you want to make a switch opperate the oposite way up, identify which type of switch you have and swop the two right hand side terminals identified in the above diagram over
:electrics:lighting:intermeadiate.gif

Diagrams

The following diagrams are how the bottom schematic diagram may be connected in the field;

:electrics:lighting:chockblockhar2w_i.gif
Click here for non-harmonized colours
:electrics:lighting:jbharm2wint.gif
Click here for non-harmonized colours
:electrics:lighting:lrblbn2wint.gif
Click here for non-harmonized colours
Notes,
Junction boxes need to be in an accessable location for inspection. Chock block must be enclosed in fitting or in a suitable enclosure above ceiling and not exposed to heat from the lamp. If a metal light switch is used, connect the earth wire to the earth terminal on the light switch and loop to the back box.

:electrics:lighting:3waysw.jpg

Light circuit with multiple intermediate switches

electrics:lighting:chockblockhar2w_3i.gif
Click here for non-harmonized colours
Notes,
Junction boxes need to be in an accessable location for inspection. Chock block must be enclosed in fitting or in a suitable enclosure above ceiling and not exposed to heat from the lamp. If a metal light switch is used, connect the earth wire to the earth terminal on the light switch and loop to the back box.

Related forum topics

No forum comments / questions currently relate to this article.


Add a comment or question about
this article in the forum:

 
Your comment or question:
First,
Existing users click here to log in.
New users click here to join FREE!
Then,
 Subject:
 Comment: