  1. enjay1999 replied to the thread Baxi Solo 3 Issue.

    Did you try what Ian said when there was a demand for heat? They do sometimes free and start spinning again.

    17 Nov 2019 at 9:00 PM
  2. enjay1999 replied to the thread Baxi Solo 3 Issue.

    There is an isolator valve either side of the pump. Turn them off undo the connections pump side, slide old pump out. If you get same...

    17 Nov 2019 at 8:56 PM
  3. enjay1999 replied to the thread Baxi Solo 3 Issue.

    If it's not spinning then then new pump time

    17 Nov 2019 at 8:51 PM
  4. enjay1999 replied to the thread Baxi Solo 3 Issue.

    Are you sure the pump is actually pumping? Sounds as if the pump is not getting heat away from the heat exchanger quickly enough. Have...

    17 Nov 2019 at 4:02 PM
  5. enjay1999 replied to the thread Gas Hob above the incoming meter? Regs Question.

    Yes would say this is fine to gas regs. Only thing I would mention, I remember there being a safety bulletin a while ago regarding the...

    16 Nov 2019 at 12:29 AM
  6. enjay1999 replied to the thread Worcester 24CDi leaking.

    Ok best of luck with it

    16 Nov 2019 at 12:13 AM
  7. enjay1999 replied to the thread No hot water, buderus 500 28c.

    Hi Manish, Is the flow rate on the hot water ok? Does the burner actually light when opening a hot tap? What happens if you leave the...

    14 Nov 2019 at 6:08 PM
  8. enjay1999 replied to the thread Worcester 24CDi leaking.

    Not sure whether you are indicating one of the pipes leaking or the big red expansion vessel. Did you re-pressure when cold to 1 bar?...

    13 Nov 2019