  1. SimonH2 posted a new thread.

    BS EN 61439-3 - what it actually says vs what people think it says

    So, we keep having conversations that come around to what people think is in BS EN 61439-3. Suggestions include that it must be single...

    Forum: Electrics UK

    11 Aug 2020 at 5:48 PM
  2. SimonH2 replied to the thread Electric Underfloor Heating.

    Is that because you don't think the boiler can cope, or there's a specific reason it can't be installed ? Is your slab already in place...

    11 Aug 2020 at 5:25 PM
  3. SimonH2 replied to the thread Getting head around RCBOs and split CU's.

    I think the big change has been in cost. When RCDs first started being mainstream, they were expensive so a big incentive to only fit...

    11 Aug 2020 at 5:10 PM
  4. SimonH2 replied to the thread Light Switch inside bathroom -Electrical Safety Certificate.

    As above, there are many light switches inside bathrooms. Most are fine. It really comes down to where it is in relation to the "wet...

    9 Aug 2020 at 9:44 PM
  5. SimonH2 replied to the thread Converting 3 phase to single phase.

    That's the sort of thing I had in mind. Users find that if one of the loads trips the breaker, the others go off. So some bright spark...

    9 Aug 2020 at 7:43 PM
  6. SimonH2 replied to the thread Converting 3 phase to single phase.

    Yes, it is indeed. The twist here is having 3 phases and (we assume) 3 poles on one MCB. Some might be tempted to swap out the 3pole MCB...

    8 Aug 2020 at 9:24 PM
  7. SimonH2 replied to the thread Converting 3 phase to single phase.

    Still allowed IF sharing protection (fuse). But since most dimmers I can recall tend to have a fuse on each output, that's not the case....

    8 Aug 2020 at 10:39 AM
  8. SimonH2 replied to the thread Converting 3 phase to single phase.

    Ooh, interesting one. I assume you mean you have a 3P circuit which you don't need to run anything 3P - so you stick (say) 3off BS1363...

    7 Aug 2020 at 10:25 PM
  9. SimonH2 replied to the thread Why is electricity more dangerous today than in 1992?.

    Indeed, it is hard to imagine why someone would make zero effort to make it the right size when that would be a once-off effort of no...

    6 Aug 2020 at 3:00 PM
  10. SimonH2 replied to the thread Why is electricity more dangerous today than in 1992?.

    We already have plastic pins on many plug in items - typically DI appliances that don't need an earth. There's no problem making plastic...

    6 Aug 2020 at 12:11 PM
  11. SimonH2 replied to the thread Why is electricity more dangerous today than in 1992?.

    It does seem strange, butvaccording to Fatally Flawed, there is not a single model tbat meets the dimentional requirements of BS1363....

    5 Aug 2020
  12. SimonH2 replied to the thread Why is electricity more dangerous today than in 1992?.

    Yup, I've been referencing the Fatally Flawed website as well. You won't find any device with BS1363 printed on it - well not correctly...

    5 Aug 2020
  13. SimonH2 replied to the thread Why is electricity more dangerous today than in 1992?.

    I wonder if it's just coincidence that ⅓ of 30mA is 10mA - the limit for expected leakage current when (IIRC) high integrity earthing is...

    5 Aug 2020