It's fairly simple, the more pipe in the floor the lower the mean water temperature. Providing you can achieve the watt/M2 required.
However, in the commercial world of contracting, where time & pipe is money, an accurate design is always done.

100mm pipe centres is not uncommon, however, with most types of PEX pipe you need to 'spoon' the bends.
 