Smoke cloak wiring to a rio + programming

Joined
8 Oct 2014
Messages
20
Reaction score
0
Country
United Kingdom
I'm having trouble with the programming, the rio won't send a negative signal when the alarm is set (smoke cloak has 2 negative inputs, -smoke & -set these are both programmed on the rio as set and intruder for trigger on the cloak. Any idea's? Thanks
 
Sponsored Links
You can use either set+ or set - on the smoke cloak !.....example set + link the set - to ov ....... Set - link the set + to 12 +
 
You can use either set+ or set - on the smoke cloak !.....example set + link the set - to ov ....... Set - link the set + to 12 +

Thanks, If I full set the alarm, (galaxy G3 48 ) Then I open the door to the garage (this is set as exit/entry) if I don't put the code in and let the alarm go in to alarm, the smoke cloak wont go off straight away there's a bit of a delay. yet if I set the alarm while in the garage (staying still) then move once its set, the cloak goes off straight away, the cloak has a pir which I know is working fine :)
 
Sponsored Links
Don't know what you are getting at ? there will be a delay if you set off in entry.
 
Don't know what you are getting at ? there will be a delay if you set off in entry.

I mean when the intruder alarm is going off (bell box sounding)

Would of thought the smoke cloak would go off straight away?

Can the smoke cloak function in part set? Cheers
 
Extra 30 second pre alarm before comms (intruder) ? On entry time out

If I do a full set then open the door the countdown starts (15 seconds) then after that the bell box goes off (30 seconds later) with the alarm still going off the smoke cloak then activates (Thr smoke cloak has its own confirmation pir)
But if I set a zone off which is set as intruder The smoke cloak goes off straight away (with pir activation) also I want the smoke cloak to be active when I part set the system as the garage is part set, then a full set is everywhere. Is there anyway I can enable the outputs to work when the system is part set? Thanks
 
What smoke cloak is it ? 4000/2000 or one of the newer ones ? When you full set it can you hear a bleep from the unit ? If so part set it , can you hear the bleep ? It may be the output you are using from the Galaxy , the ones I've connected where on GARDTEC and premier panels ...
 