Smoke cloak wiring to a rio + programming

What smoke cloak is it ? 4000/2000 or one of the newer ones ? When you full set it can you hear a bleep from the unit ? If so part set it , can you hear the bleep ? It may be the output you are using from the Galaxy , the ones I've connected where on GARDTEC and premier panels ...

Yeah when I stand in the garage and full set the alarm I here the smoke cloak bleep once when I set the alarm, then when I unset the alarm I here the smoke cloak beep twice. When I part set the alarm the smoke cloak doesn't beep when set or unset, the smoke cloak is a VALI 5 and the alarm is a Galaxy G3-48, the cloak is connected to the rio on outputs 1021 (set) & 1022 (intruder) both outputs are set as latched. Must be something to do with the programming?
 
Sponsored Links
Sounds like output is full set only

Oh right, will maybe if I turn groups on and make the garage a group and then the output can function when the alarm is set?

Another thing is, on the smoke cloak the red (heater led) is flashing, everything works fine, but on the intruder alarm it's saying the smoke cloak fault zone is open ?

Many thanks
 
From memory it flashes when heating up, are the batteries connected ? I think the new units have a usb interface so you can find out what is at fault.
 
Sponsored Links
From memory it flashes when heating up, are the batteries connected ? I think the new units have a usb interface so you can find out what is at fault.

In the manual it just says when the led is on its heating. But it's funny that the fault output on the vali is open. Doesn't say there's a tamper, when I look at zone 2028 on the keypad it's named as smoke cloak fault, and then the zone is open. Must be something to do with the flashing led? Yes batteries are connected, power ok lef is on. So is the battery led also fluid is fine.... Thanks it's baffling
 
Thomasthomas23";p="3215806 said:
Extra 30 second pre alarm before comms (intruder) ? On entry time out
If I do a full set then open the door the countdown starts (15 seconds) then after that the bell box goes off (30 seconds later) with the alarm still going off the smoke cloak then activates (Thr smoke cloak has its own confirmation pir)/quote]
That is quite usual, it's called 'two ply entry'

The first sound is - come on, turn me off or get a full alarm.

The second sound is - I warned you, here it is.
 