I would like to run a soil pipe through a pitched roof void so i would be grateful for your advice to help me work out if i can get it done and still have have enough room for insulation. The roof void is 180mm deep and the soil pipe is 110mm in diameter. How much gap do i need to leave for ventilation between the insulation and the roof tiles? Would 10mm be enough? if so that leaves 30mm of insulation over and under the soil pipe. Does that sound like it is enough?
IMAG1230.jpg
 
Last edited:
Sponsored Links
50mm required air gap.
I don't understand why you're running a soil pipe between rafters? Is it for venting purposes or does it form part of the 'wet' side of the system?
 
50mm required air gap.
I don't understand why you're running a soil pipe between rafters? Is it for venting purposes or does it form part of the 'wet' side of the system?
It is a part of the 'wet' system. My bathroom is on the first floor and my kitchen and extension is right underneath it. I am trying to find a route for the soil pipe from the upstairs toilet to the manhole outside so that it is out of sight. The alternative is to box the soil pipe in the space underneath the extension roof which will be unsightly so i'd like to avoid that if i could
 
Last edited:
just break the insulation over the pipe along it's length and add 50mm of ridged insulation under the ceiling ties of the extension
 
Sponsored Links
just break the insulation over the pipe along it's length and add 50mm of ridged insulation under the ceiling ties of the extension
Thanks Chappers. Can you please explain a bit more. What is ridged insulation? is it something like Kingspan or Celotex? Are you suggesting to insulate above or under the soil pipe? Thanks
 
yeah celotex or kingspan,
Insulate your roof space as normal apart from where the pipe runs and only insulate under the pipe leaving your air gap above the pipe and then make up the insulation under the ceiling in the extension with 50mm
 
Thanks! This is the drawing I plan to send to my bco for approval. Any comments welcome
IMAG1233.jpg
 
should be fine, is the ceiling below already finished, if not just use 25mm insulated plasterboard to reduce any cold bridging you may get due to the reduced insulation around the pipe.
 