Can I replace O ring on Grundfos UPS2 15-50?

Joined
7 Apr 2016
Messages
10
Reaction score
0
Location
Camberley
Country
United Kingdom
Hi, Could anyone tell me, if one is able to obtain a replacement o ring to go between the pump head and the body?

I've done a small amount of hunting online but no luck in finding a part no....

(I ask this because occasionally when in the process to diagnosing a blocked pump Id like to inspect the impellers, without having to worry about the seal leaking if I were to put the old head back on after cleaning, instead of replacing the head)

Thanks in advance.
 
Sponsored Links
Hi, Could anyone tell me, if one is able to obtain a replacement o ring to go between the pump head and the body?

Simply Bearings <simplybearings.co.uk> stock O rings in a very wide range of diameters and cross-sections. I managed to fix a leaking water meter with one from them when I had had no joy from the manufacturer.
 
the seals are very reliable, I have changed countless Grundfoss pump heads and have never seen a seal leaking
 
Sponsored Links
thanks for your replies.

ianmcd - would you be worried about the seal leaking if you were to put the old head back on with the old seal. I too have changed many heads over but in that case would always fit the replacement head with the new seal.

The scenario I had i mind:

Friday night job, Old Dorris's down the road heating pump has packed up. No spare on the van, I can remove pump head and give it a good clean out. Put old head back, heatings back on. Question is: Is it going to leak?
 
thanks for your replies.

ianmcd - would you be worried about the seal leaking if you were to put the old head back on with the old seal. I too have changed many heads over but in that case would always fit the replacement head with the new seal.

The scenario I had i mind:

Friday night job, Old Dorris's down the road heating pump has packed up. No spare on the van, I can remove pump head and give it a good clean out. Put old head back, heatings back on. Question is: Is it going to leak?
removed and replaced the same grundfoss pump heads on many boilers and never had a leak, Wilo however will be like the dancing fountains
 