Hi, I have mounted my pyronix sensors (KX100DP-WE) I do a walk test and it has really difficulty picking me up (all 5 sensors) i literally have to jump around like a loon before it beeps on panel to confirm.. any ideas?
The pet immune ones basically ignore things below a cirtain hight along with heat mass therefore if your move the sensor higher then the pet free area rises too, which means a person could walk under its range without triggering it.
I’ve been to a few of these where they don’t work as they have been fitted in the ceiling corner, once moved to the correct hight they work fine.
Thx no they weren't.. I checked the height on site and it says from 1.8m-2.4m for ceiling.. mine is dot on 2.4m.. one thing.. I took out the inner sensor cover (looks removable) seems to work better.. not sure if it's a good idea thou... Nothing in write up about it.
Try cutting out the top plastic "bar" in the pet filter. It does improve the detection rate somewhat, but they still leave a lot to be desired IMO. If you put the panel into walk test, the LED should light up with every activation for testing purposes.