Another light switch question

Joined
7 Feb 2019
Messages
13
Reaction score
0
Country
United Kingdom
So whilst replacing old light switches with new ones (nothing fancy this time just replacing scruffy ones with white ones) 2 rooms in my house have 2 wires going in to one of the ports and 1 wire going into the other. One has 2 into common and 1 in to l1 and the other 2 in to l1 and 1 into common. I’m assuming one of the switches is wired incorrectly and am curious as to why they would be wired like this? Again an assumption is that this is to continue the circuit through the house but why do this at the switch and not in one of the junction boxes? Help appreciated!
 
Sponsored Links
2 rooms in my house have 2 wires going in to one of the ports and 1 wire going into the other.
Really we need to see what other wires, if any are in the enclosure.
It could be the two wires go to two lights.

One has 2 into common and 1 in to l1 and the other 2 in to l1 and 1 into common. I’m assuming one of the switches is wired incorrectly
With one-way switches it doesn't matter which way round they are.

and am curious as to why they would be wired like this? Again an assumption is that this is to continue the circuit through the house but why do this at the switch and not in one of the junction boxes? Help appreciated!
What do you mean "one of the junction boxes"? How many are there?
Why use an unnecessary junction box when it can be done at the switch?
 
Thanks for the swift reply. There are halogen spots in the room. Could it be that the room has been split in to two sets of lights? There’s only one switch and it switches on all of the lights in the room. The wires are all grey externally with red internal insulation.
 
And reference to the ‘when it can be done at the switch’ I’m not an electrician so am
Curious as to why it’s done at the switch and not elsewhere. Don’t know if it is right or wrong. My loft has quite a few junction boxes...
 
Sponsored Links
Thanks for the swift reply. There are halogen spots in the room. Could it be that the room has been split in to two sets of lights? There’s only one switch and it switches on all of the lights in the room. The wires are all grey externally with red internal insulation.
It could be.

And reference to the ‘when it can be done at the switch’ I’m not an electrician so am
Curious as to why it’s done at the switch and not elsewhere. Don’t know if it is right or wrong.
Well, your question is not really valid.

You might as well ask "Why do it at a junction box or elsewhere when it could be done at the switch?"

My loft has quite a few junction boxes...
Ok.

DIYers seem to love junction boxes. I don't know why. Perhaps they don't realise wires can be connected at switches and fittings.
 
I’ll trace all the wires to get a better idea, but assuming it’s one set of lights, why would I have 2 wires to one of the ports? Is typically as I initially thought? That is keeping the circuit when the switch is off?
 
Again an assumption is that this is to continue the circuit through the house
If that assumption is correct then it is likely that the neutrals would also be present and connected together.

Two wires in one connector could be, as said, they go to two (lots of) lights,
one used to be for that and now both are connected together at both ends - just because it can be, as it is safe for spare wires.

Disconnect one and see what stops working.
 