Accenta g4 mini

Joined
2 Aug 2019
Messages
3
Reaction score
0
Country
United Kingdom
I have recently wired and installed the above security panel with 2 led keypads. On first power up both key pads alarms go off until you enter 0123 as per manufacturers instructions. Now when I enter p9999 to enter engineers mode the last 9 creates a different keypad tone and I am unable to enter the engineers mode. This is a brand new install and components. Any help would be great, thanks.
 
Sponsored Links
That is odd.
Seems like the engineer code has been changed.

Try defaulting panel to factory settings:
1. Power down panel.
2. Remove wiring from SET output and PA input.
3. Fit shorting wire between SET and left-hand PA terminal.
4. Power up.
5. Wait for alarm to start.
6. Power down panel and then restore original wiring.

This should change engineer code back to 9999.

Let me know how you get on.

Matt
 
Which set and pa? There is 2, a pa and set in a block of 4 at the top of the panel and a set next to the bell connections and a Pa+ next to the tamp connections.
I did think about this but with it being brand new I thought it couldn’t be this.
I appreciate your help.
 
Hi, sorry for the confusion. Its the terminals at the bottom of the panel. Left hand PA and SET.

It's worth a try. If not the panel is defective.

Matt
 
Sponsored Links
Your a star mate! The reset has done it. I originally thought about doing it but with it being fresh out the box it shouldn’t need it and secondly I was unsure which two, set and pa terminals to use.
Once again thank you mate.
 