Nest heatlink into Ideal c30 boiler

Joined
17 Nov 2019
Messages
4
Reaction score
0
Country
United Kingdom
Hi
We have just had a new boiler installed but the Nest is not working. I don't think its been wired in correctly. Please could someone check the pictures uploaded and let me know.

Thanks in advance for any help.
20191116_130540.jpg
20191116_124232.jpg
 
Sponsored Links
Wrong in several ways.

To do properly you will need some 5 core flex, or another piece of 3 core.
 
Ok. I can get this. Please could you help with what needs to be done. We will be using the Nest thermo via a stand and not mounted on wall.
 
With 5 core flex between the Nest heatlink and the boiler:

Colour - Boiler - Nest Heatlink

Green/Yellow: Boiler earth - Nest earth
Brown: Boiler L - Nest L
Blue: Boiler N - Nest N
Black - Boiler Room Stat - Nest 2
Grey - Boiler Room Stat - Nest 3

Doesn't matter which way round the wires at the boiler room stat terminals are.

If using 3 core flex, then the existing 3 core is for E-L-N as above, then another separate piece of 3 core flex is
Green/Yellow: Boiler earth - Nest earth
Blue- Boiler Room Stat - Nest 2
Brown - Boiler Room Stat - Nest 3

However if the existing mess was installed by someone you paid, then they should be the ones installing it properly, or you need a refund from them.
 
Sponsored Links
Your a star! I will do this myself as I don't trust they will do properly. I'm already trying to get a refund for other stuff. I should have guessed when he pulled up on a horse!
 

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Back
Top