I had to replace a 50w bulb in a 12v spotlight track fitting, after replacing the light still didn't work and I noticed that part of the silver/metal covering on the connector is missing, as shown in image, could this be the reason, thanks
 

Attachments

  • IMG_20191124_164633802.jpg
    IMG_20191124_164633802.jpg
    158.6 KB · Views: 252
Sponsored Links
Sponsored Links
Thanks, thought it might be the built in transformer but obviously
the connector will be the cheaper option
 
What does that missing bit of silver do, I presume part of the circuit but not sure how,,?
 
The low voltage and high current, plus heat and sometimes poor quality connections mean they do often fail. Might be worth your while fitting a new lampholder and swapping to LED, if an LED can be used in that fitting. They are much lower current.
 
Harry. I am thinking about going to led, when getting a new connector , as u know only
about 5w then, there are 4 lights on the track so will be about 20w instead of 200w
Thanks
 
There are others more expert than me on LED conversion, discuss it with them first before going too far.

200w is an awful lot of heat and wasted power..
 
No such thing.
No such thing…
621FFAF6-861B-4887-A28E-A9DF05828853.jpeg


I was making it easier for the OP to get the appropriate part.

As you don’t seem to have anything constructive to do, could you call Toolstation and about 1000 other sellers and tell them to change their description?
Thank you. Have a nice day.
 
Tool station are WRONG. You are wrong to promote something that is wrong.
 
Five different pin arrangements for MR16 lamps MR = multiple faceted reflector and 16 refers to the diameter of the front of the lamp.

MR16figure3.jpg

(a) 2-pin
(b) medium screwbase with integral transformer
(c) intermediate screwbase with integral transformer
(d) turn and lock
(e) bayonet


copied from HERE
 
Be it electronic transformer, electronic ballast, MR16, or a host of other items where the old name has migrated to new products, giving the name used by the advertisers is the right way, and if MR16 will find the part, then that is the right word to use in google even it not the right name.

Today it is very hard to find true LED MR16 lamps, as most LED lamps don't have the reflector.

As to move to LED there are 4 options to allow the move.
1) Original powered from a toroidal transformer then simply swap. Being careful to select non DC lamps, and most are not DC anyway.
2) Original powered from an electronic transformer with range 50 - 200 VA swap the power pack for either a toroidal transformer, or an electronic transformer marked 0 - 50 VA or use a DC power pack often called incorrectly a driver, a driver should be current control, but it seems 12 volt voltage regulated devices also called drivers. Best option electric wise is the toroidal transformer, as many lamps marked 50 Hz.
3) Swap to GU10 fittings, and do away with the transformer.
4) Get special GU5.3 230 volt bulbs, not recommended as too easy fit wrong ones latter, and the fitting may not be insulated to the correct amount for 230 volt use.

This link shows likely the best option but depends if it will physical fit.
TLT50SLASH1.JPG
also this electronic version will work it can go down to zero output,
LTYT50.JPG
the output is not likely to be 50 Hz so there is a slim chance it could with LED lamps become a small transmitter, so should be placed close to the bulbs, there is normally a maximum cable length. It is supplied with 300 mm of 12 volt lead, should not really exceed that length although think it is unlikely to cause a problem.

Since you say spot like track which may not be insulated well enough for 230 volt, I would swap holder which is damaged and if not already a toroidal transformer then fit either toroidal transformer or the electronic one shown. The electronic one can be dimmed.
 
giving the name used by the advertisers is the right way, and if MR16 will find the part, then that is the right word to use in google even it not the right name.

l disagree. All that does is promote the use of incorrect use If age. Googling GU5.3 base gets plenty of hits.
 