Drayton wiser wiring help

Joined
24 Jan 2021
Messages
8
Reaction score
0
Country
United Kingdom
Hi,

This is my existing wall mounted control could someone help me with the wiring to the drayton wiser please?

Cheers
 

Attachments

  • IMG-20210123-WA0005.jpg
    IMG-20210123-WA0005.jpg
    124.4 KB · Views: 150
Sponsored Links
Which Drayton wiser backplate do you have?
 
So from existing to Drayton Wiser:

L to L
N to N
NO1 to CH1 on
NO2 to CH2 on

The common isn’t required at the Wiser, but may need to go to one of the L’s, just depends if it’s a link wire or not.
 
Sponsored Links
Yeah the common is a link wire, Ill give this a go shortly - thanks
 
I've tried that and it won't call the boiler to heat, if I turn the other danfuss unit on it calls the boiler then the wiser will work, any ideas?
 
What other Danfoss unit? A thermostat? If so, this must be set to maximum or wires linked together.
 
I have a second danfuss in the bedroom whats the best way to sort set it to link the wires?
 
Just some connector blocks, wago’s or if you are worried about decoration, put the 2 wires in the same terminal at the stat.
 
So take the front plate off and then move all the live wires to L, sorry if this seems like dumb questions.
 
Or can I just put a link wire between the channel and live?
 
Yes, or to switch, or do what you’ve said and place a link. Once this is done, the Wiser will take over the temperature.
 

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Sponsored Links
Back
Top