Hello guys

My surveyor says to get RC35 Padstones.

I asked Builders Merchants if they can supply RC35.

Answer they gave?. 'Presumably', they do. Not helpful. If they sell the stuff and can't be specific, how can I know what to get?.

Are there different standards for Padstones?.

Please advise.

Thank you.
 
Sponsored Links
The number 35 refers to the crushing strength of the concrete (in Newtons per sq. mm). Most padstones are actually RC50 so RC35 is a bit on the low side.
 
Thank you.

What size padstone for 215 mm wall, please?.
 
Thank you.

What size padstone for 215 mm wall, please?.
Sorry, no idea.
It depends on the load the beam is putting onto the padstone, and also the bearing capacity of your brickwork. Your SE should advise on the size of padstone; if he hasn't told you the size required, he's not done his job.
 
Sponsored Links
Did your "surveyor" mean something like this? Ask at Jewsons if any in stock

upload_2021-7-7_0-4-16.png
 
Thank you.

I guess someone will know more about this attachment than I do.

Please have a look.
 

Attachments

  • universal beam sorted.jpeg
    universal beam sorted.jpeg
    254.1 KB · Views: 102
  • sheet 2 .jpeg
    sheet 2 .jpeg
    137.7 KB · Views: 113
  • sheet 3 .jpeg
    sheet 3 .jpeg
    92.3 KB · Views: 101
  • sheet 4.jpeg
    sheet 4.jpeg
    162.5 KB · Views: 94
  • sheet 5.jpeg
    sheet 5.jpeg
    127.5 KB · Views: 97
  • sheet 6.jpeg
    sheet 6.jpeg
    179.5 KB · Views: 90
  • sheet 7.jpeg
    sheet 7.jpeg
    101 KB · Views: 108
Its about time your Structural Engineer learnt to use up to date design codes. BS449 was replaced by BS 5950 and then years later by BS EN 1993.

The masonry design code is also out of date but still used by some older engineers.
 
Yes, 449 and 5950 are superceded, but I've still seen a few figures done under 449. It's still accepted by many LABC checking engineers for smaller domestic work; the advantage is that its quicker but it is also conservative, and smaller sections can be obtained by using the later Codes.
I stick with 5950 and have never had any queries raised. EC 3 potentially gives even lighter sections, but I rarely use that, not being into pain.
 
I never hired a such surveyors before for this type of work but I began to feel he could be more involved, and what you have quoted here confirms my thinking. I am fed up with him that is why I put my queries here.

As far as section drawings are concerned, the best info I have found for Padtones is what I have attached here. I will consider the Codes you have given me.

Thank you.
 

Attachments

  • Padstones.jpeg
    Padstones.jpeg
    158.5 KB · Views: 88
Last edited:
That bloke has specified a concrete lintel as an alternative. Use those and you don't need padstones.

Alternatively, as the steel beam is so small, use 2 solid blue bricks instead of a padstones.
 
For a 2500 span you could probably set it on two of my mum's jam tarts and it would be ok.
 
So what's the characteristic compressive strength of your Mum's jam tarts (in N/mm²)?
 
I have a 3.2m span, single storey, on a 100x150x250mm padstone which is barely more than a brick. As above I think anything will do really.
 
So what's the characteristic compressive strength of your Mum's jam tarts (in N/mm²)?
Not sure. I just know they would be classed as dangerous weapons if you were caught with one outdoors.
 

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Sponsored Links
Back
Top