Hi guys i wonder if anyone can give me some helpful advice
i have just picked up a 3 seater sofa with 2 inbuilt electric motors , each motor has a plug in 24v transformer lead

one of the leads powers both sides but the other lead will not power either side

i have check for power coming from the transformer with a meter and there is power i have also checked the lead from the transformer to the jack for continuity which there is in both of the 2 cores...

so im at abit of a loss on what could be wrong
 
Sponsored Links
what type of "leads" and what do they connect between? photo will help a lot
 
Here is some pics ive got the lenght of cable out the middle to rule that out for sure
 

Attachments

  • 20210711_173619.jpg
    20210711_173619.jpg
    444.5 KB · Views: 96
  • 20210711_173652.jpg
    20210711_173652.jpg
    509 KB · Views: 101
have you checked continuity between the Low Voltage plug and the ends of the cut lead.? If there is a break it's much more likely to be where the lead enters the plug than at some point in between.
 
Sponsored Links
i have just picked up a 3 seater sofa with 2 inbuilt electric motors , each motor has a plug in 24v transformer lead

one of the leads powers both sides but the other lead will not power either side

i have check for power coming from the transformer with a meter and there is power i have also checked the lead from the transformer to the jack for continuity which there is in both of the 2 cores...

so im at abit of a loss on what could be wrong
You wrote "2 inbuilt electric motors , each motor has a plug in 24v transformer lead"
and
"one of the leads powers both sides but the other lead will not power either side"
Indications are that there is only one transformer (as supplied) - "i have check for power coming from the transformer"

If "one of the leads powers both sides" - what is the problem?

Is the sofa "used"?
It may be that there were originally two transformers, with one powering each side, but the sofa may have been rewired so that only one transformer is now required !

I suggest that you look underneath the sofa to see how things have been (re)wired. (Tipping the sofa upside down will probably be required.)
 
Why ( who ) cut the lead to the ELV plug ?

Mains 230 V is LV Low Voltage ELV = Extra Low Voltage
 

Attachments

  • upload_2021-7-12_8-31-24.png
    upload_2021-7-12_8-31-24.png
    609 KB · Views: 59
Why ( who ) cut the lead to the ELV plug ?

Mains 230 V is LV Low Voltage ELV = Extra Low Voltage

I think the OP did, as he said in the post just before my previous, where I believe he was trying to type:

"Here are some pics. I've CUT the length of cable out the middle to rule that (ie the cable) out for sure.
 