Hi,im putting a power shower in,it had one in some time ago,so the wiring is in,there is a feed from the cold storage in loft,just need to t into the hot from cylinder.question is,how far down from the draw off on top of cylinder to i need to t in? if its too high it wont draw off will it? and what size pipe? keep the 22mm right up to shower then 15mm or 22mm then stright to 15mm?
also the wiring is from the power shower to 3amp fused switch in airing cuboard? i wont do wiring,just asking.
can i use t with 2 22mm and one in 15mm to loft then down to shower?
ben
 
Sponsored Links
If your teeing in to draw off then 6 inches minimum below open vent and it must be first before any taps.
3amp yes and as for size have a look at MFI but 15mm is usually the norm
 
Sponsored Links
cheers namsag,so this is ok and will have as good pressure as an essex flange?
also will there be water in pipe from top of cylinder after i ran off taps etc?
ben
 